Message
DIMM
configuration on
each CPU should
match.
Embedded NIC x and
NIC y :
OS NIC= <ENABLED
|DISABLED> ,
Management
Shared NIC=
<ENABLED
|DISABLED>
Error 8602 -
Auxiliary Device
Failure. Verify
that mouse and
keyboard are
securely
attached to
correct
connectors.
Gate A20 failure. Faulty keyboard controller;
Invalid
configuration
information -
please run SETUP
program.
Invalid PCIe card
found in the
Internal_Storage
slot!
28
About Your System
Causes
Invalid memory
configuration on a
dual-processor system.
The memory module
configuration for each
processor must be identical.
The OS NIC interface is set
in BIOS. The Management
Shared NIC interface is set
in management tools.
Mouse or keyboard cable is
loose or improperly
connected.
Defective mouse or keyboard. Ensure that the mouse or
faulty system board.
An invalid system
configuration caused a
system halt.
The system halted because
an invalid PCIe expansion
card is installed in the
dedicated storage controller
slot.
Corrective Actions
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module
Installation Guidelines" on
page 83.
Check the system
management software or the
System Setup program for
NIC settings. If a problem is
indicated, see
"Troubleshooting a NIC" on
page 131.
Reseat the mouse or
keyboard cable.
keyboard is operational.
See "Troubleshooting a USB
Device" on page 130.
See "Getting Help" on
page 157.
Run the System Setup
program and review the
current settings. See "Using
the System Setup Program
and UEFI Boot Manager" on
page 41.
Remove the PCIe expansion
card and install the
integrated storage controller
in the dedicated slot. See
"RAID Battery (Optional)"
on page 115.