Table 1-3. System Messages (continued)
Message
Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.
Alert! Node
Interleaving
disabled! Memory
configuration
does not support
Node
Interleaving.
Causes
The optional iDRAC6
has hung.
The optional iDRAC6 was
remotely reset while system
was booting.
After AC recovery, the
optional iDRAC6 takes
longer than normal to boot.
The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a memory
module has failed) so that
node interleaving cannot be
supported. The system will
still run, but without node
interleaving.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. Check
other system messages for
additional information for
possible causes. For memory
configuration information,
see "General Memory
Module Installation
Guidelines" on page 115.
If the problem persists,
see "Troubleshooting System
Memory" on page 154.