MERLIN LEGEND Communications System Release 6.0
Installation 555-660-140
Installing the Control Unit

AC Power and Grounding

— Make sure that the material meets local building codes.
Dimensions
— With Systimax wiring: 7 ft. wide by 4 ft. high
— Without Systimax wiring: 6 ft. wide by 3 ft. high
Installing the Backboard
When you are certain that the backboard meets the requirements indicated
above, or is the new lightweight plastic material backboard with preassembled
equipment in place, attach the backboard to the wall.
Use the following mounting hardware:
For a wood mounting surface, use wood screws.
For brick, cinderblock, or concrete, use masonry anchors.
For plaster or plasterboard, use toggle bolts.
For sheet metal, use sheet-metal screws and attach them to the
structural members.
NOTE:
The mounting hardware should resist a combined pullout force of at least
650 pounds (295 kilograms).
AC Power and Grounding
Proper power and grounding are essential for the system to run correctly and
safely.
!
CAUTION:
If any of the following requirements are not met, the customer must
contact a licensed electrician. Do not install the system until all
requirements are met.