MERLIN LEGEND Communications System Release 6.0
Installation 555-660-140
Initializing and Testing the System
Testing the System
Testing Outgoing Dial-Repeating Tie Trunks
Perform this test for dial-repeating tie trunks that are two-way or outgoing only.
If you are testing dial-repeating two-way tie trunks, perform the incoming test as
well.
To test outgoing dial-repeating tie trunks, follow the steps below:
At any telephone that has access to a dial-repeating tie trunk, press
!

the first tie-trunk button.
The red LED next to the pressed tie-trunk button lights.
Pick up the handset. (In Hybrid/PBX systems with pooled tie trunks,
!

press an SA button and dial the pool dial-out code.)
The green LED next to the selected button lights.
Dial the tie-trunk number of the extension where someone is
!

waiting for your call.
You should hear ringing.
When the person answers, verify that you have good two-way
!

communication, then hang up.
The green LED should turn off, the red LED should turn off, and
another red LED may turn on.
Repeat Steps 1 through 4 for each outgoing or two-way
!

dial-repeating tie trunk.
Testing BRI Trunks
Perform the testing described in " 800 NI-BRI Module Problems" in Chapter 4 of
Maintenance and Troubleshooting .
Testing Selected System Features
This section provides procedures to test the following system features: