Error Logs, the Access Log, and System inventory
Table 2-1:- (Continued)
Error
Code
Description
6COA
DS1 SLIP ALARM:
Slip count reached 88.
6COB
DS1 HARDWARE INOPERATIVE:
DS1 hardware is not operating properly,
If this is the only 100D (DS1) module, or
if this is the module designated to have
the active clock, its TDM bus clock
generator was not activated.
7001
PRI SVC AUDIT TIMEOUT:
7002
PRI SVC STATE INCONSIST:
PRI D-CHNL INOPERATIVE:
7003
Action
Troubleshoot the T1 trunk. If problem
persists, escalate to your technical
support organization.
Maintenance
Slot
Current hr
If problem persists, escalate to your
technical support organization.
Troubleshoot the PRI trunk and report to
service provider; otherwise, no action
required. If problem persists, contact
your technical support organization.
Troubleshoot the PRI trunk and report to
service provider; otherwise, no action
required. If problem persists, contact
your technical support organization.
Troubleshoot the PRI trunk and report to
service provider; otherwise, no action
required. If problem persists, contact
your technical support organization.