Introduction to System Maintenance
regular pliers
wrist grounding strap
CAUTION:
Electrostatic discharge can destroy or severely damage the
integrated circuits in the power supply, processor, and
modules. Should you ever need to open a module and
handle the circuit board, use the wrist strap to connect your
wrist to a suitable ground first.
replacement parts recommended by your technical support
organization
Removing the Control Unit Housing
1.
Disconnect AC power from each auxiliary power unit at the wall outlet.
Disconnect AC power from each carrier by disconnecting the power
2.
cord at the wall outlet.
Remove the housing (see Figure 1-1):
3.
If the existing control unit is a MERLIN II Communications System,
remove the housing as follows.
Remove the front housing from each carrier by pulling the
a.
bottom-front towards you. When it releases, remove it by lifting
up as shown in Figure 1-1.
b.
Remove the top from each carrier in the system by pushing it
straight up from the front.
If the existing control unit is a MERLIN LEGEND Communications
System, remove the housing as follows.
a. From both sides of the control unit, pry the clips from the
housing, using a screwdriver if difficult to reach.
Equipment 1-3