Control Unit Problems
Persistent Module Problems
If any of the module tests fail and replacing the module does not clear the
trouble, one of the following could be the cause:
Several modules could be faulty.
The connector on the carrier could be faulty.
Busy-Out and Reset
Before running any module test, be sure to busy-out or reset the module. This
procedure discontinues service from the module that you are about to test.
The Busy-Out procedure is preferred because it does not drop calls in
progress:
Busy-out discontinues service from the module being tested to each
line and extension only as they become idle. Busy-out does not
disrupt calls in progress.
Reset discontinues service to all equipment instantly. All in-progress
calls are dropped.
Once you complete module testing, restore it as described later in this section
under "Restore." Restoring a module terminates the busy-out or reset
condition.
4-26
Module Problems