Control Unit Problems
Busy-Out or Reset
Interrupting the Test
Test Fail
ure
Restore
Quick-Reference Procedure
Menu
Maintenance
Demand Test
Busy-out or reset the module being tested prior to
beginning the test.
NOTE:
Both Busy-out and Reset are in the Slot menu,
which you can access by doing the following from
the console:
Menu
Maintenance
See "Busy-Out and Reset" earlier in this chapter
for additional information.
You can interrupt the test (both Test Once and
Repetitive) by selecting Exit.
If the test fails, record the errors on the repair tag and
replace the module.
Restore the module if it successfully completes all
module tests and the errors no longer occur.
NOTE:
Restore is in the Slot menu, which you can
access by doing the following from the console:
Menu
Maintenance
See the "Restore" procedure earlier in this
chapter for additional information.
Slot
Int Loopback
Slot
Slot
Type the slot number
Test Once or Test Repetitive.
Module Problems
Enter
4-35