Electrical Connection - AEG Competence E2191-4 User Information

Electrolux user information built-in electric oven competence e2191-4
Hide thumbs Also See for Competence E2191-4:
Table of Contents

Advertisement

Electrical Connection

The oven is designed to be connected to 230-240V~(50Hz) electricity
supply.
The oven has an easily accessible terminal block which is marked as
follows:
Letter L
Letter N
E
1
This oven must be earthed!
The cable used to connect the oven to the electrical supply must
comply to the specifications given below.
For UK use only
Connection
via
Cooker Control Circuit
It is necessary that you install a double pole switch between the oven
and the electricity supply (mains), with a minimum gap of 3mm
between the switch contacts and of a type suitable for the required
load in compliance with the current regulations.
The switch must not break the yellow and green earth cable at any
point.
Important
After installation and connecting, the cable must be placed so that it
cannot at any point reach a temperature of more than 50°C above the
ambient temperature.
Before the oven is connected, check that the main fuse and the domes-
tic installation can support the load; and that the power supply is prop-
erly earthed.
The manufacturer declines any responsibility should these safety
measures not be carried out.
-
Live terminal
-
Neutral terminal
-
Earth terminal
Min. size
Cable/flex
2
6 mm
Cable/flex
type
PVC/PVC
twin and earth
Fuse
min: 40A
max: 45A
49

Advertisement

Table of Contents
loading

Table of Contents