Understanding The Rotary Switch; Rotary Switch Positions - Fluke 289 User Manual

True-rms digital multimeters
Hide thumbs Also See for 289:
Table of Contents

Advertisement

287/289
Users Manual

Understanding the Rotary Switch

Select a primary measurement function by positioning the rotary
switch to one of the icons around its perimeter. For each
function, the Meter presents a standard display for that function
(range, measurement units, and modifiers). Button choices made
in one function do not carry over into another function. The
model 289 offers two additional functions: low ohms (Y) and
low impedance (LoZ) ac volts. Each position shown in Figure 3 is
described in Table 4.
Figure 3. Rotary Switch
10
Table 4. Rotary Switch Positions
Switch
Position
L
V
T
U
N
S
P
A
X
est03.emf
Y
Function
AC voltage measurement using a low input
impedance (model 289 only)
AC voltage measurements
AC millivolt measurements
DC and ac+dc voltage measurements
DC millivolts, ac+dc millivolt, and
temperature measurements
Resistance, continuity, and conductance
measurements
Diode test and capacitance measurements
AC, dc and ac+dc amps and milliamps
measurements
AC, dc and ac+dc microampere
measurements up to 5,000 A
Resistance measurements with 50e range
(model 289 only)