Table 9. Stopped Recording Display
8:10pm
123.45 VAC
REL
1.75
0
100
200
Start Time :
06/10/07 07:23:55
Duration : 3 days 14 Hrs 47 mins
6
Interval Samples: 135
Reference: 121.70 VAC
5
Save
Item
Description
Stopped Icon indicating the recording session is
A
stopped.
B
Time and date when the recording began.
Length (duration) of time recording session was
C
in progress.
Number of event records detected.
D
E
Reference value for relative measurements.
F
Number of interval records detected.
1
06/13/07
Stopped
Recording
VAC
Auto Range
300
400
500 VAC
2
3
Events:53
4
Trend
Close
est34.eps
Using Communications
You can use the IR communication link and FlukeView Forms
software to transfer the contents of a meter's memory to a PC.
When using a PC-to-meter IR (infrared) communication link, refer
to the FlukeView Forms Installation Guide or the on-line help.
The Meter will log in real-time mode to a connected
computer running FlukeView Forms. In addition, the
Meter allows the user to log to internal memory and
connect to the computer later for download.
FlukeView Forms allows you to place the data into standard
(default) or customized forms. The forms display the data in table
and graph form, as well as show user comments. You can use
these forms to satisfy ISO-9000 and other documentation
requirements.
True-rms Digital Multimeters
Using Communications
Note
55