Closing Up; Supplementary Information; Fifth Relay Output (2Nd Ignition Or 2Nd Accessories Or 2Nd Crank Output); Ignition-Controlled Door Locks - ProStart CT-3200 Installation Manual

Automatic transmission multi-channel remote starter system
Hide thumbs Also See for ProStart CT-3200:
Table of Contents

Advertisement

8.
Idle Mode: Make sure the vehicle properly goes into Idle Mode.
Most comebacks are the result of misunderstandings about how a product works or performs. Take
the time to properly explain all functions and features to the customers before they leave the
premises. Doing this will save time and money.

Closing Up

Use tie-wraps or screws to properly secure the Module and keep the wiring away from any moving
parts such as the Parking Brakes or Steering Column Shafts. Mount all switches in good and
accessible locations where they do not risk getting kicked or hit accidentally. Any under hood
wiring should be split loomed and tie strapped away from moving parts and heat sources.
Always make all your connections before plugging in the Module. Keep in mind to plug the fuses
as the last step before the initial powering of the Module. Be sure to test all functions properly
before closing up the installation.
Make sure the Warning Label is applied on a visible place under the Hood.

Supplementary Information

The following features can be programmed according to the user's needs and the requirements of
the installation.
Fifth Relay Output (2nd Ignition or 2nd Accessories or 2nd Crank
Output)
N N
ote: Only one set of pins can be used at a time.
ote: Only one set of pins can be used at a time.
Cautio
n: The relay output rating on this Unit is 25 A at mo
sometimes draw up to 50 or 60 A, causing the 30 A fuse to blow. Always check your circuit with a
proper measuring device.

Ignition-controlled Door Locks

This feature will automatically lock all
position and the Brake Pedal is pressed. When the Ignition Key is turned to the
Doors will automatically unlock.

Secure Lock

This feature allo
ws the Module to control certain OEM factory Alarm systems that use the factory
Lock wire to arm the Alarm and the Unlock wire to disarm it.
If Secure Lock is disabled (Option 1), the Module will still disarm b
If Secure Lock is enabled (Option 2), upon receiving a remote
the Doors (disarming the factory Alarm); 1/2 sec. after remote start it will re-lock the Doors. 4
CT-3200 Installation Guide
The Module comes equipped with a high-current
programmable 5
power a 2
The Unit uses three sets of pins. Each set of
pins has a function. To activate one of the three
possible 2
(supplied) on one of the three sets of pins and
(supplied) on one of the three sets of pins and
connect the green 14 AWG wire either to the 2
connect the green 14 AWG wire either to the 2
Ignition wire, to the Accessories wire or to the
Ignition wire, to the Accessories wire or to the
Crank wire of the vehicle.
Crank wire of the vehicle.
st. Defective OEM solenoid switches can
Doors as soon as the Key is turned to the
relay which can be used to
th
Ignition, Accessory, or Crank Wire.
nd
nd
outputs, place the Jumper
IGNITION ON (RUN)
OFF
efore remote-starting the vehicle.
signal the Module will
START
nd
nd
position, the
UNLOCK
P. 11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProStart CT-3200 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF