22. Miscellaneous
22. Miscellaneous
22.1 Fan control
22.1.1
Composition
DC power supply
fan motor (FM1)
Ozone ventilation
fan motor (FM3)
22.1.2
Function
A. Fusing fan motor
• Fusing fan motor discharges heat generated from the interior parts (including the DC
power supply, fusing unit, toner cartridges/K, and motor drives) out of the main body to
prevent the interior temperature from rising inordinately.
• Air passageway is formed on top of the DC power supply, in the duct inside the toner car-
tridge rail, and below the print head housing. No air flows through areas around the toner
cartridges. This effectively prevents toner from scattering.
B. DC power supply fan motor
• Discharges heat generated from the interior parts (including the DC power supply, inter-
mediate transfer belt section, toner cartridges/C, M, Y, and motor drives) from the main
body to prevent the interior temperature from rising inordinately.
C. Ozone fan motor
• Discharges heat generated from the print head from the main body to prevent the print
head temperature from becoming inordinately high.
• Removes ozone produced from the toner cartridges and charging section.
• Air passageway is formed on top of the DC power supply, in the duct inside the toner car-
tridge rail, and below the print head housing. No air flows through areas around the toner
cartridges. This effectively prevents toner from scattering.
86
Fusing fan motor (FM2)
A011T2C578AA
Theory of operation Ver.1.0 Nov. 2007
DC power supply fan motor (FM1)
Fusing fan motor (FM2)
Ozone ventilation
fan motor (FM3)
4138to2111c0