Provision for Ventilation
The room containing the cooker should have an air supply in accordance
with the current edition of BS 5440: Part 2:. The room must have an
opening windows or equivalent; some rooms may also require a permanent
vent. If the room has a volume between 5 and 10m
vent of 50cm
2
effective area unless it has a door which opens directly to
the outside. If the room has a volume of less than 5m
air vent of 100cm
2
effective area. If there are other fuel burning appliances
in the same room, the current edition of BS 5440: Part 2: should be
consulted to determine air vent requirements. Ensure that the room
containing the cooker is well ventilated, keep natural ventilation holes or
install a mechanical ventilation device (mechanical cooker hood). Prolonged
intensive use of the appliance may call for additional ventilation, for example
opening of a window, or more effective ventilation, for example increasing
the level of mechanical ventilation where present. This cooker is not fitted
with a device for discharging the products of combustion. Ensure that the
ventilation rules and regulations are followed. Excess steam from the oven,
vents out at the top back edge of the cooker, so make sure that the walls
behind and near the cooker are resistant to heat, steam and condensation.
Your cooker must stand on a flat surface so that when it is in position the
hob is level. When in position check that the cooker is level by using a
spirit level and adjust the 2 feet at the rear and the 2 feet at the front if
necessary. It is important that the cooker is stable and level for the overall
cooking performance.
Remember that the quantity of air necessary for combustion must never
be less than 2m
/h for each kW of power (see total power in kW on the
3
appliance data plate).
In the other cases, if there are more gas appliances in the room, or if it
is not possible to have a direct natural ventilation and should there be the
necessity of a natural indirect ventilation or a forced one, you would need
to consult a technician that will provide to the installation and the execution
of an eventual ventilation system, in relation to the current directives.
The position if the openings should not disturb the persons in the room,
and evacuation of the combustion products is forbidden via any pipe
already used by other appliances.
Note: if the appliance does not have the thermocouple the openings should
be the 100% bigger, with a minimum diameter of 200cm
the current directives.
min. 100cm
.
2
Gas Safety (Installation & Use) Regulations
It is the law that all gas appliances are installed by competent persons in
accordance with the current edition of the Installation & Use Regulations.
It is in your interest and that of safety to ensure compliance with the law.
In the UK, CORGI registered installers work to safe standards of practice.
The cooker must also be installed in accordance with the current edition
of BS 6172. Failure to install the cooker correctly could invalidate the
warranty, liability claims and could lead to prosecution.
Fig. 12
3
, it will require an air
3
, it will require an
2
, in relation to
elettroventilatore
min. 100cm
.
2
1/2"
F
Fig. 13

GAS CONNECTION

This appliance must be installed in accordance with the regulations in
force and only in a well-ventilated space. Read the instructions before
installing or using this appliance.
IMPORTANT
This cooker is supplied for use on Natural Gas Only and cannot be used
for any other gas without modification.
Conversion for use on LPG and other gases must only be undertaken by
a qualified person. For information for use on other gases contact your
local Service Centre.
The cooker must be installed by a qualified person in accordance with the
current edition of the Gas Safety (Installation and Use) (Amendment)
Regulations
and the relevant building/I.E.E. Regulations.
Failure to install the appliance correctly could invalidate any manufacturers
warranty and lead to prosecution under the above quoted regulations.
In the UK, CORGI registered installers are authorised to undertake the
installation and service work in compliance

ELECTRICAL CONNECTION

This appliance must be installed by a qualified person in accordance
with the latest edition of the IEE Regulations and in compliance with
the manufacturer instructions.
Ensure that the voltage is the same as that stated on the rating plate. The
rating plate can be found on the back cover .
WARNING! THIS APPLIANCE MUST BE EARTHED
The cooker must be connected to a suitable cooker control unit incorporating
a double pole switch having a contact separation of at least 3mm in all
poles, which is adjacent to, and not more than 1.25m away from the
cooker and easily accessible.
• The electric cable should not be in contact with parts that can reach
temperatures over 50 C above the ambient temperature.
REPLACEMENT OF THE CABLE
In case the cable is damaged, replace it in accordance with the following
instructions:
- switch the appliance off at the control switch
- open the box of the supply board as described on the picture below;
- unscrew the clamp"A" fixing the cable;
- replace the cable with one of the same length and in accordance with
the specification described on the table;
- the 'green-yellow" earth wire must be connected to the terminal "
and it must be about 10 mm longer than the live and neutral wires;
- the "blue" neutral wire must be connected to the terminal marked with
letter "N";
- the live wire must be connected to the terminal marked with letter "L".
9
F
"