3Com Dual 56K User Manual page 123

Dual 56k lan modem
Hide thumbs Also See for Dual 56K:
Table of Contents

Advertisement

Disconnecting Calls
123
Disconnecting Calls
Disconnect timers are set via the Data Call Parameters window. Specifically, you
Automatically Using
can set the following parameters:
Timers
Minimum Call Duration
Enter the minimum length of a call that must be reached before the Dual 56K LAN
Modem detects inactivity on the connection and then starts an inactivity timer. The
default is 120 seconds (two minutes), which is also the lowest value allowed for
this field.
Idle Timeout
In the fields Disconnect a data call after how long of an inactivity period?, enter
the number of seconds after which a call should be disconnected due to inactivity.
This timer is initiated once the minimum call duration is satisfied and no further
activity is detected. To prevent a data call from being disconnected due to
inactivity, enter 0. The default for an automatic call is 420 seconds (seven
minutes). The default for a manual call is 900 seconds (15 minutes).