5
GS2: Status information
Order
1
Notifying of switching to Standby mode
2
Whether the unit has already been adjusted or not
3
With/without backup of adjustment data
4
Power-down information
5
Temperature information (TEMP1)
Abnormality in RST2 (power decrease of the
6
DC-DC converter)
7
IC4 communication failure
8
EEPROM communication failure
9
Failure in audio
10
Communication failure of the volume IC
11
Backup-ROM communication failure
12
Failure in temperature information (TEMP1)
13
Activation of panel protection
14
(Reservation)
15
Hour meter
• Power-down information
Power-down point
Data
0
No power-down
1
Not used
2
P-POWER
3
SCAN
4
SCN-5V
5
Y-DRIVE
6
Y-DCDC
7
Y-SUS
8
ADRS
9
X-DRIVE
A
X-DCDC
B
X-SUS
C
DIG-DCDC
D
Reservation
E
Reservation
F
Power-down point not identified
5
6
Data
Size
1 byte
1 byte
1 byte
2 byte
3 byte
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
9 byte
7 byte
PDP-434CMX
6
7
Remarks
1: Successfully switched to Standby mode
0: Adjusted, 1: Not adjusted
0: With backup, 1: Without backup
1st byte: 1st PD, 2nd byte: 2nd PD
000 to 255
0: Normal, 1: Shutdown process caused by an abnormality
completed, 2: In the process of displaying a warning against
shutdown caused by an abnormality
0: Panel protection not activated, 1: Panel protection being
activated
∗ ∗ ∗ ∗ ∗ ∗ ∗ ∗ ∗
1st-5th bytes: Hour, 6-7th bytes: Minute
7
8
A
B
C
D
E
F