(Continued from previous page.)
Setting
SCAN
DURATION
SCAN/SKIP
MODE
SCREEN
BLANKER
HOTKEY
COMMAND
MODE
HOTKEY
SET LOGOUT
TIMEOUT
Determines how long the focus dwells on each port as it cycles
through the selected ports in Auto Scan Mode (see F7 SCAN,
page 32). Key in a value from 0–255 seconds, then press [Enter].
Default is 10 seconds; a setting of 0 disables the Scan function.
Selects which computers will be accessed under Skip Mode (see
F5 SKP, page 31), and Auto Scan Mode (see F7 SCAN, page 32).
Choices are:
ALL - All the Ports which have been set Accessible (see Port
Access, page 67);
POWERED ON - Only those Ports which have been set
Accessible and are Powered On;
QUICK VIEW - Only those Ports which have been set Accessible
and have been selected as Quick View Ports (see SET QUICK
VIEW PORTS, page 28);
QUICK VIEW + POWERED ON - Only those Ports which have
been set Accessible and have been selected as Quick View Ports
and are Powered On.
The default is ALL.
If there is no input from the console for the amount of time set with
this function, the screen is blanked. Key in a value from
0–30 minutes, then press [Enter]. A setting of 0 disables this
function. The default is 0 (disabled).
Enables / Disables the Hotkey Command function in case a
conflict with programs running on the computers occurs. The
default is ON.
This setting selects the Hotkey invocation keys (see Keyboard Port
Operation, page 34). Choices are:
[Num Lock] + [–] or [Ctrl] + [F12]
The default is [Num Lock] + [–].
If there is no input from the console for the amount of time set with
this function, the Operator is automatically logged out. A login is
necessary before the console can be used again.
This enables other Operators to gain access to the computers
when the original Operator is no longer accessing them, but has
forgotten to log out. To set the timeout value, key in a number from
0–180 minutes, then press [Enter]. If the number is 0 (zero), this
function is disabled. Default is 0 (disabled).
Chapter 4. Local Console Operation
Function
(Continues on next page.)
27