Table 1. Features and specifications (continued)
Acoustical noise emissions:
v Sound power, idling: 5.5 bel
v Sound power, operating: 6.0 bel
Environment:
v Air temperature:
– Server on: 10° to 35°C (50° to 95°F)
Altitude: 0 to 915 m (3000 ft)
– Server on: 10° to 32°C (50° to 90°F)
Altitude: 0 to 915 m (3000 ft) to 2134
m (7000 ft)
– Server on: 10° to 28°C (50° to 83°F)
Altitude: 2134 m (7000 ft) to 3050 m
(10000 ft)
– Server off: 5° to 45°C (41.0° to
113°F)
– Shipping: -40° to 60°C (-40° to
140°F)
v Humidity (operating and storage):
– Server on: 20% to 80%, Maximum
dew point 21°C, Maximum rate of
change 5°C/hr.
– Server off: 8% to 80%, Maximum
dew point 27°C
Heat output:
Approximate heat output in British thermal
units (Btu) per hour:
v Minimum configuration: 693 Btu per
hour (203 watts)
v Maximum configuration: 2788 Btu per
hour (817 watts)
8
System x3400 M2 Types 7836 and 7837: Installation and User's Guide
Up to eight expansion slots
(depending on the model):
v Six expansion slots on the system
board
– Four PCI Express Gen2 x8 slots
(two x8 links and two x4 link)
– One PCI Express Gen2 x16 slot
(x8 link)
– One PCI 32-bit/33 MHz slot
v One PCI Express Gen1 x8 (x4) slot on
the one-slot extender card
v Two PCI-X 32-bit/64-bit 133/100/66/
MHz slots on the two-slot extender
card
Video controller:
v Matrox G200eV video on system
board
v Compatible with SVGA and VGA
Diagnostic LEDs:
v Fan
v Microprocessor
v Memory
v Power supply
v Voltage regulator module (VRM)
v PCI
v Battery
v IMM heartbeat
v Enclosure manager heartbeat
Electrical input:
v Sine-wave input (50 or 60 Hz) required
v Input voltage and frequency ranges
automatically selected
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
v Input kilovolt-amperes (kVA)
approximately:
– Minimum: 0.21 kVA (all models)
– Maximum: 0.82 kVA
Notes:
1. Power consumption and heat output
vary depending on the number and type
of optional features installed and the
power-management optional features in
use.
2. These levels were measured in
controlled acoustical environments
according to the procedures specified
by the American National Standards
Institute (ANSI) S12.10 and ISO 7779
and are reported in accordance with
ISO 9296. Actual sound-pressure levels
in a given location might exceed the
average values stated because of room
reflections and other nearby noise
sources. The declared sound-power
levels indicate an upper limit, below
which a large number of computers will
operate.