Setting The Temperature Controls - Electrolux EILFU21GS Use And Care Manual

Electrolux 21 cu.ft. upright freezer model eilfu21gs use and care guide
Hide thumbs Also See for EILFU21GS:
Table of Contents

Advertisement

Setting the Temperature Controls

Cool Down Period
For safe food storage, allow four (4) hours for freezer to cool down completely. The freezer will run continuously for
the first several hours.
Electronic Temperature Control
The electronic temperature control is located on the freezer door. Temperature is factory preset to provide
satisfactory food storage temperatures. Refer to the SETTING FREEZER CONTROL Quick Reference
Guide below for more details.
Press to start or
cancel the fast
freeze feature.
Press to
decrease the
temperature
setting
Display
Priority
"HI"
Alternating "E1"
and temperature
Alternating "CE"
and temperature
Alternating "E2"
and temperature
Actual
Temperature
Set Temperature
SETTING FREEZER CONTROL
SETTING FREEZER CONTROL
Press and
Turns the
hold for 3
temperature
seconds to
display ON or
toggle F or C
OFF.
in the display.
Indicates the
Indicates the
temperature was
door has been
above +23°F (-9°C)
open 5 minutes
for at least one
or more.
hour.
ALARM FUNCTION TABLE
Visual Alarm
3
"HI Temp" LED ON and
mute sounds LED flashes
2
mute sounds LED flashes; 1
second set temperature, 1
second "E1"
1
mute sounds LED flashes; 1
second set temperature, 1
second "CE"
4
mute sounds LED flashes; 1
second set temperature, 1
second "E2"
6
power fail LED on and mute
sounds LED flashes
5
door ajar LED on and mute
sounds LED flashes
Installation
Press to
Press to turn the
mute
sounds ON or OFF.
audible
When the LED is ON,
alarms.
the sounds are muted.
Indicates the
power was
interrupted.
Alarm Status
Action(s) Required
Freezer temperature
Press the mute sounds key
over the safe limit
to stop the audible alarm
Fail Safe Mode
Check thermistor status
Press the mute sounds key
to stop the audible alarm
Communication Error
Check connection between
UI and ECU. Press the mute
sounds key to stop the
audible alarm
Stuck Key Error
Check membrane keys.
Press the mute sounds key
to stop the audible alarm
Cabinet greater than 10
Press the mute sounds key
degrees over the SET
to stop the audible alarm
TEMP. at power up.
Door open for more than
Press the mute sounds key
5 minutes
to stop the audible alarm
Press and hold
for 3 seconds to
start or cancel
control lock.
Press to
increase the
temperature
setting
9

Advertisement

Table of Contents
loading