Maytag MGDZ400TQ - 27" Gas Dryer Use And Care Manual page 8

Use and care guide
Table of Contents

Advertisement

Available languages

Available languages

t
72"
(162.9 crn)
J
(2.5crn)
5Y2"** --_-
,_- 1"
(14crn)
(2.5 crn)
_-
.Jj
(66.6 cm)
*Required
spacing
**For venting
out the side, 1"/2.5
cm) spacing
is allowed.
Mobile
home
- additional
installation
requirements
This dryer is suitable
for mobile
home installations.
The installation
must conform
to the Manufactured
Home Construction
and Safety Standard,
Title 24 CFR, Part 3280 (formerly
the Federal Standard
for Mobile
Home Construction
and
Safety, Title 24, HUD
Part 280) or to the Canadian
Manufactured
Home Standard,
CAN/CSA-Z240
MH.
Mobile
home installations
require:
[]
Metal
exhaust
system hardware,
which
is aw3ilable
for purchase from your dealer.
[]
Mobile
Home Installation
Kit Part Number
346764.
See '"]bols
and Parts" section
for
information
on ordering.
[]
Special
provisions
must be made in mobile
homes to introduce
outside
air into the dryer.
[he opening
(such as a nearby window)
should
be at least twice
as large as the dryer
exhaust
opening.
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow
these instructions can result in death,
fire, or electrical
shock.
120 Volt, 60 Hz., AC only, 15- or 20-amp
fused electrical
supply
is required.
A time-delay
fuse or circuit
breaker
is recommended.
[t is also recommended
that a separate circuit
serving
only this dryer be provided.
GROUNDING
INSTRUCTIONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.