Plan Vent System; Connect Vent - Maytag MGDE300VF - Performance Series 27-in Gas Dryer Use And Care Manual

Use and care guide
Hide thumbs Also See for MGDE300VF - Performance Series 27-in Gas Dryer:
Table of Contents

Advertisement

Available languages

Available languages

Special provisions for mobile home installations
The exhaust
vent must be securely
fastened
to a noncombustible
portion
of the mobile
home
structure
and must not terminate
beneath
the mobile
home. Terminate
the exhaust
vent
outside.
Determine
vent path
Select the route that will provide
the straightest
and most direct
path outdoors.
Plan the installation
to use the fewest
number
of elbows
and turns.
When
using elbows
or making
turns, allow
as much
room as possible.
Bend vent gradually
to avoid kinking.
Use the fewest 90 ° turns possible.
Determine
vent
length
and elbows
needed
for best drying
performance
Use the following
vent system chart to determine
type of vent material
and hood
combinations
acceptable
to use.
NOTE:
Do not use vent runs longer than those specified
in the Vent system chart.
Exhaust systems longer than those specified
will:
Shorten the life of the dryer.
Reduce performance,
resulting
in longer drying
times and increased
energy
usage.
The vent system chart provides
venting
requirements
that will
help to achieve
the best
drying performance.
Vent
system
chart
NOTE: Side and bottom
exhaust
installations
have a 90 ° turn inside the dryer. To determine
maximum
exhaust
length,
add one 90 ° turn to the chart.
Number
of 90 °
Type of vent
Box or Iouvered
Angled hoods
turns or elbows
hoods
0
Rigid metal
64 ft (20 rn)
58 ft (17.7 rn)
Flexible
metal
36 ff (11 m)
28 ff (8.5 m)
1
Rigid metal
54 ft (16.5 m)
48 ft (14.6 m)
Flexible
metal
31 ff (9.4 m)
23 ff (7 m)
2
Rigid metal
44 ft (13.4 m)
38 ft (11.6 m)
Flexible
metal
27 ft (8.2 m)
19 ft (5.8 m)
3
Rigid metal
35 ft (10.7 m)
29 ft (8.8 m)
Flexible
metal
25 ft (7.6 m)
17 ft (5.2 m)
4
Rigid metal
27 ft (8.2 m)
21 ft (6.4 m)
Flexible
metal
23 ft (7 m)
15 ft (4.6 m)
1.
2.
3.
Install exhaust
hood.
Use caulking
compound
to seal exterior
wall opening
around
exhaust
hood.
Connect
vent to exhaust
hood.
Vent must fit inside exhaust
hood.
Secure vent to exhaust
hood with 4" (10.2 cm) clamp.
Run vent to dryer location.
Use the straightest
path possible.
See "Determine
vent path" in
"Plan Vent System." Avoid
90 ° turns. Use clamps
to seal all joints.
Do not use duct tape,
screws or other fastening
devices that extend
into the interior
of the vent to secure vent.
Z
Z'I