Plan Vent System - Maytag MGDC215EW0 Installation Instructions Manual

29" and 27" wide models
Hide thumbs Also See for MGDC215EW0:
Table of Contents

Advertisement

Available languages

Available languages

Exhaust
h oods:
[]
Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes,
or snow).
Recommended
St_ _les:
Louvered hood
Acceptable
Style:
Box hood
Angled hood
Elbows:
[]
45 ° elbows provide better airflow than 90 ° elbows.
Bet
Clamps:
[]
Use clamps to seal all joints.
[]
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
improper venting can cause moisture and tint to collect
indoors, which may result in:
[] Moisture damage to woodwork,
furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning
problems and health problems.
See "Venting Kits" for more information.
Plan Vent System
Recommended
exhaust
installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
B
-'11
B
_H
A. Dryer
B. Elbow
C, Wall
D. Exhaust hood
E. Clamps
E Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
I. Optional side exhaust outlet
Optional
exhaust
installations:
27" Wide Models can be converted to exhaust out the right side,
left side, or through the bottom (4-way vent kit). Each kit includes
step-by-step
instructions.
For ordering information, see "Venting
Kits."
!
Fire Hazard
Cover unused exhaust holes with a manufacturer's
exhaust cover kit,
Contact your local dealer,
Failure to follow
these instructions can result
in death,
fire, electrical shock, or serious injury,
A
B
c
A, Standard rear offset exhaust installation
B. Left- or right-side exhaust installation
(27" wide models only)
C. Bottom exhaust installation (27" wide models only)
10