Main menu
(continued)
Sub menu
IN MONITOR DISPLAY
OFF
ON
POSITION
TOP
BOTTOM
CHAR. COLOR
CMD
WHITE
BLUE
GREEN
YELLOW
CYAN
RED
GRAY
MAGENTA
*
3
When colors selected by commands are set to "OFF," the IMD character string is not displayed.

CONTROL

Sub menu
CONTROL
LOCAL
REMOTE
*
LOCAL ENABLE
1
DISABLE
INPUT
FUNCTION
INPUT+FUNC.
*
PROTOCOL VER.
2
V3.1
V4.0
RS-485 ID SETUP
0-126
RS-485 STX&ETX
OFF
ON
*
1
Only available when "REMOTE" is selected under "CONTROL."
*
2
The monitor supports version 3.1 and 4.0 of the TSL UMD PROTOCOL provided by Television System LTD.

HOURS METER

Sub menu
OPERATION
XXXXXXh
LCD
XXXXXXh
*
1
"XXXXXX" indicates up to 262800 hours (approx. 30 years). "OVER" is indicated when the number of hours is 262800 or higher.
Settings
Enables IMD display.
Selects the position for the IMD display.
<TOP>
<BOTTOM> Bottom
Selects IMD font color.
<CMD>
<WHITE>
<BLUE>
<GREEN>
<YELLOW>
<CYAN>
<RED>
<GRAY>
<MAGENTA> Magenta
Settings
Selects operation. (with control lock)
<LOCAL>
<REMOTE> Remote operation enabled (controls using RS-232C or RS-485). (Front
Selects whether to enable or disable INPUT SELECT and FUNCTION button
operations when "REMOTE" is selected under "CONTROL."
<DISABLE>
<INPUT>
<FUNCTION>
<INPUT+FUNC.> Enables INPUT SELECT and FUNCTION button operations.
Selects version of the TSL protocol.
Sets the unit ID number to use in RS-485 communication.
Select RS-485 interface command format (→page 46).
<OFF> STX and ETX need not be placed.
<ON>
STX and ETX must be placed.
Settings
*
1
Displays the number of hours it has been on.
*
1
Displays the number of hours that the backlight has been on.
Description
Top
Color specified by command
White
Blue
Green
Yellow
Cyan
Red
Gray
The underlined values are factory preset setting values.
Description
Front panel operation is enabled (including controls that use the GPI
function)
panel operation is locked)
• Power On/Off, VOLUME operations, GPI control and menu display are
available when the lock is engaged.
• Only "CONTROL/LOCAL ENABLE" menu items are available when the
lock is engaged.
• The rotary knob is disabled and set values cannot be changed when the
lock is engaged.
• The "LOCAL ENABLE" setting determines operations in lock mode.
• The key icon appears in the operation status display, menu display (main
menu, FUNCTION menu, INPUT SELECT menu), picture adjustment
menu display, and function display screens when the lock is engaged.
[MARKER]
MARKER
16:9
4:3
BACK
NORMAL
CENTER
CROSS
COLOR
WHITE
Disables INPUT SELECT and FUNCTION button operations.
GPI MARKER1
95%(16:9)
GPI MARKER2
Enables INPUT SELECT button operations.
95%(16:9)
Enables FUNCTION button operations.
MENU EXIT
SEL.
ENTER
RETURN
Description
*
3
Key icon
OFF
4:3
OFF
OFF
OFF
RETURN
41