Main menu
(continued)

VIDEO CONFIG

Sub menu
*
*
GAMMA SELECT
1
2
FILM GAMMA
COLOR TEMP.
*
SHARPNESS MODE
5
*
SHARPNESS H
5
SHARPNESS V
*
5
*
I-P MODE
6
*
1
In split-screen display, changes are not reflected to the still image in the main window.
*
2
This menu is grayed out when the same item is assigned to the GPI input terminal pin and GPI CONTROL is set to ENABLE.
*
3
When selecting USER 0 - 63
1) Push the rotary knob (USER changes to blue).
2) Use the rotary knob to select 0 to 63 and press the rotary knob.
*
4
Selecting "VAR1", "VAR2" and "VAR3" engages the WB adjustment mode (→page 26).
*
5
The following sharpness values are available and the settings for the selected input signal is displayed.
Adjustment status during selection appears at the bottom left of the screen.
1) VIDEO system input (VIDEO) (the factory defaults are SHARPNESS MODE: LOW and SHARPNESS H/V: 0)
2) HD inputs other than (1) above (the factory defaults are SHARPNESS MODE: HIGH and SHARPNESS H/V: 0).
3) SD inputs other than (1) above (the factory defaults are SHARPNESS MODE: LOW and SHARPNESS H/V: 0).
*
6
To use the "SUB WINDOW" (→page 34) function,
1) Change settings after exiting the "SUB WINDOW" function.
2) It is recommended to use "MODE2" for handling fast video.
Settings
STANDARD
Selects gamma curve.
FILM
<STANDARD> Standard mode (2.2 gamma value)
STDIO/PST
<FILM>
<STDIO/PST> Color emphasis mode (2.35 gamma value)
• When FILM is selected, the
VARICAM
Selects type of FILM gamma mode.
OTHER
<VARICAM>
<OTHER>
(Gamma curve image)
*
USER 0 - 63
3
Selects color temperature.
D93
<USER 0 - 63> Adjustable settings 0 - 63
D65
D56
<D93>
VAR1
<D65>
VAR2
<D56>
VAR3
<VAR1> WB adjustment mode
<VAR2> WB adjustment mode
<VAR3> WB adjustment mode
HIGH
Selects the width of outline correction edge.
LOW
<HIGH> Narrow edge
<LOW>
0 - 30
Sets horizontal outline correction. The item display moves to the lower part of the
screen during adjustment.
0 - 30
Sets vertical outline correction. The item display moves to the lower part of the
screen during adjustment.
MODE1
Selects IP conversion mode. (see "IP mode" (→page 26).)
MODE2
<MODE1>
<MODE2>
The underlined values are factory preset setting values.
Description
Film mode
mark is displayed for the operating status.
For VARICAM use
Other
OTHER
Video Gamma
Input Level
(equivalent to a color temperature range of 3,000 K - 9,300 K)
Equivalent to a color temperature of 9,300 K
Equivalent to a color temperature of 6,500 K
Equivalent to a color temperature of 5,600 K
*
4
*
4
*
4
Wide edge
Intra-frame interpolation
Intra-field interpolation
VARICAM