Download Print this page

HP StorageWorks 7100 - Virtual Array Appendix page 27

Appendix a. disk array controller log
Hide thumbs Also See for StorageWorks 7100 - Virtual Array:

Advertisement

Event
Event
Number
Name
(dec/hex)
563/0x233
PDM Add
564/0x234
Disk Redundant Path Found
565/0x235
Disk Redundant Path Lost
566/0x236
State Changing Start
567/0x237
State Changing End
568/0x238
Disk Driver Created
569/0x239
Disk Driver Deleted
570/0x23a
Hot Plug Event
571/0x23b
New Device Found
572/0x23c
Old Device Lost
573/0x23d
Warning Indicator Activated
574/0x23e
Warning Indicator Deactivated
575/0x23f
PDM Label Table Mismatch
576/0x240
Uploaded mode parms were
defaulted
577/0x241
Start multi disk loss scan
578/0x242
Multi disk loss detected
579/0x243
Exit multi disk loss reset
580/0x244
Policy generated relocation
error
581/0x245
Insufficent space for policy
relocation
582/0x246
Frontend Fibre Channel Hung
Port Event
583/0x247
DDM Disk Change Event
584/0x248
Repair of corrupted eeprom
done.
Predictive
Suspected
Maintenance
Components
Implication
Y
Ignore
Disk
Y
Disk
Y
Disk
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
NA
None
Y
Ignore. should
controller
be other prior
failure events
Y
Ignore. should
controller
be other prior
failure events
Y
Ignore. should
controller
be other prior
failure events
Y
NA
None
Y
NA
None
Y
Ignore
None
Y
Ignore
None
Y
Ignore
Controller
EEPROM
Description
The actual blockSize is output in the verbose log
eventInfo.
N
A PDM has been added for the specified device.
This could mean that a previously downed drive is
being re-added, or that a PDM was added for a
newly added drive.
N
A redundant path to an already known drive has
been discovered.
N
A redundant path to an already known drive has
been lost.
N
The state changing bit has been asserted.
N
The state changing bit has been deasserted.
N
A PDD (proxy and real) has been instantiated for a
disk.
N
A PDD (proxy and real) has been destroyed for a
disk.
N
A generic hot plug event occurred. See the event
unique description for more information.
N
A new device was discovered by CFMhot.
N
A device CFMhot already knew about has
disappeared.
N
One of the warning indicators has been actviated.
Check the extended event information for more
information.
N
One of the warning indicators has been deactviated.
Check the extended event information for more
information.
N
A PDM, during instantiation, came up with different
basic information. One possible cause is
downloading unsupported mech FW that doesn't
conform to the required capacity point for drive
category.
Y
The midplane EEPROM mode parameters region
contains a revision that is older than the revision
expected by current firmware. As a result, some
mode parameters were set to their default values
since there was no saved value present in the
EEPROM.
N
A backend scan was started to detect a multiple disk
loss condition because of a raid 5 DP write failure.
If a multiple disk loss is detected, raid 5 DP writes
will not be allowed to proceed. Another log entry
will indicate if the condition is detected. No
additional entry will be made otherwise.
N
A multiple disk loss was detected. Raid 5 DP writes
will not be processed until this condition is cleared.
N
This controller is exiting from the excessive disk
missing condition. Enough of the missing disks
have been restored to attempt normal operations.
Y
A policy sponsored data relocation failed.
Y
There is not enough space to perform a policy
sponsored relocation.
N
This error code indicates that the Front End Fibre
Channel port appears to be in a HUNG state. The
port will be reset in an attempt to recover from the
event. Additional information about the event is
placed in the extended info area of the log.
N
This error is being used to indicate (in the extended
info field) changes in Dump Disk Manager disk
change event processing. This code should be
removed before release.
N
The eeprom region located at 0 or 48 was corrupted
and repaired with it's backup copy at 48 or 0
respectively.

Advertisement