Event
Event
Number
Name
(dec/hex)
356/0x164
Local Controller Failed DRAM
Address Decode Test
357/0x165
Remote Controller Failed
DRAM Address Decode Test
358/0x166
Controller Failed Background
ROM checksum test
359/0x167
Scrub policy detected error
360/0x168
New controller firmware was
downloaded
361/0x169
Mode Parameters changed
362/0x16a
Shared memory recovered
error
363/0x16b
Shared-memory controller
error
364/0x16c
Shared-memory checksum
error
365/0x16d
Flash failure resulting from
command sent to flash
366/0x16e
DRAM Checksum failure
during download
367/0x16f
Flash Checksum failure during
download
368/0x170
Download Semaphore request
failed
369/0x171
Download image failed
validation
370/0x172
Family Image compare failed
371/0x173
Download failed on slave
Predictive
Suspected
Maintenance
Components
Implication
Y
Ignore if
DRAM SIMM,
recovered by
Controller
reset or power on
Y
Ignore if
DRAM SIMM,
recovered by
Controller
reset or power on
Y
Ignore if
ROM,
recovered by
Controller
reset or power on
Y
Ignore - should
Disk drive
be preceded by
Drive errors
Y
Ignore - Operator
None
activity
Y
Ignore - Operator
None
activity
Y
Ignore; other
Controller
errors will follow
if significant
Y
Ignore if
Controller
recovered by
reset or power
cycle
Y
> 1 in 6 mo.
Controller,
SDRAM,
midplane, disks
Y
N.A.
Y
N.A.
Y
N.A.
Y
N.A.
Y
N.A.
Y
N.A.
Y
N.A.
Description
error appears in the first 4 bytes of the controller
serial number field of this log record. The LUN
appears in the fifth byte of the controller serial
number, and the length of the affected area in 512
byte blocks appears in the last 3 bytes. The FRU
field reports the FRU of the drive corrected.
N
This error code indicates that the DRAM SIMM on
the local controller failed the DRAM address decode
test during the poweron process. Specifically, the
DRAM SIMM on the primary controller failed the
decode test.
N
This error code indicates that the DRAM SIMM on
the remote controller failed the DRAM address
decode test during the poweron process.
Specifically, the DRAM SIMM on the secondary
controller failed the decode test.
N
This error code indicates that the ROM on the local
controller failed the ROM checksum test done in the
background during idle time. The firmware stored
in the ROM is corrupted.
N
This error code indicates that an error was returned
to the Scrub policy by a device read. It is logged to
provide information about the cause of the error.
Additional information about the error from the
device should precede this entry.
N
New controller firmware was successfully installed
in all controllers present in the subsystem.
N
A mode select command was processed and it
changed one or more changeable mode parameters
in the subsystem.
N
This error code indicates that some non-fatal error
appeared in the shared-memory error queue. The
two words of this queue entry will be placed in the
log entry extended info area.
N
This error code indicates that some fatal error
appeared in the shared-memory controller error
queue. The two words of this error entry will be
placed in the event extended info area. After all
entries in the queue have been processed, the
subsystem will undergo a short reset.
N
This error code indicates that a fatal checksum error
appeared in the shared-memory controller error
queue. The two words of this queue entry will be
placed in the event extended info area. After all
entries currently in the queue have been processed,
the subsystem will undergo a reset.
Y
This error code results if we get an error during the
programming, erasing or reading flash. So if we get
any error when commanding flash to perform a task
that we interpret as Flash not responding correctly,
we will log this error.
N
If during the download sequence of events we fail
the checksum performed in DRAM this error will
result. This event occurs before we try to copy to
FLASH.
Y
If after copying the download image into the flash
part(s) the checksum of the image fails this error
will result.
N
Only one download command from the host can be
executed at a time. If a host request for download
occurrs while one is already active the redunant
requests will get this error.
N
The download image sent from the host is validated
by the Download Sequncer as to it validity. If the
data received does not appear to be firmware image
then this error will result.
N
If the firmware image to be downloaded has a
different family image value then the currently
running image and this is a online download, then
this error will result.
Y
In a dual controller environment the command to

Advertisement

loading
Need help?

Need help?

Do you have a question about the StorageWorks 7100 - Virtual Array and is the answer not in the manual?

Questions and answers