Event
Event
Number
Name
(dec/hex)
298/0x12a
Disk Reassign Completed
299/0x12b
Disk Reassign Cancelled
300/0x12c
No Error On Disk Media After
Medium Error
301/0x12d
Incompatible RAM Image
Revision
302/0x12e
Controller Presence Detect
Faulted Off
303/0x12f
No Interrupts From Other
Controller
304/0x130
Disk Interface Disconnect
305/0x131
Disk Downed
306/0x132
Data Unavailable
307/0x133
Insufficient Optimal Space For
Rebuild
308/0x134
Rebuild Restarted
309/0x135
Rebuild Executing
310/0x136
Rebuild Preempted
311/0x137
Cancel Rebuild Started
312/0x138
Rebuild IO Priority Changed
313/0x139
Non-Member Drive Removed
Predictive
Suspected
Maintenance
Components
Implication
Problem -
Unsupported
Disk
Y
See disk drive
Disk
vendor's reassign
rate spec.
Y
Ignore
None
Y
Ingore unless
Disk Drive
medium error
recurs
Y
Ignore - Operator
None
Error
Y
Single
Controller,
Occurrance
Midplane
Y
Single
Controller,
Occurrance
Backplane
Y
Ignore - Disk
Disk Drive
compatibility
problem
Y
Ignore - Operator
None
or Host activity
Y
Ignore - See
None
accompanying
errors
Y
Ingore - See
None
accompanying
errors
Y
Ignore
None
Y
N.A.
None
Y
N.A.
None
Y
Ingore - Operator
None
or Host activity
Y
Ignore - Host
None
activity
Y
Ignore - Operator
None
activity
Description
data transfer phase. This will cause disconnects to
be disabled for the entire on the interface, thus
causing degraded drive performance. This event
may also indicate that the firmware could not enable
queueing on this drive, which also causes
disconnects to be disabled on the interface. The
reported FRU is the slot number. (See the "Disk
Interface Queuing Disabled" event.)
N
This event indicates that the array firmware
successfully completed a data reassignment
(sparing) operation. The reported FRU is the slot
number. This is informational only, not an error
condition.
N
This event indicates that a data-reassign (sparing)
operation was cancelled by the array firmware. The
most likely reason is that the firmware detected that
the disk was reset and in need of reconfiguration.
The reported FRU is the slot number. This is
informational only, not an error.
N
This event indicates that the PDD's media test has
determined that media for which a drive had
reported a MEDIUM ERROR is actually OK. The
data stored at the affected LBA may or may not
have been recovered. The reported FRU is the slot
number.
N
This event indicates that the NVRAM image stored
on the volume set when it was shutdown is not
compatible with the current version of firmware.
The image cannot be uploaded and the resulting
system state is NO_MAPS for this volume set.
Y
he presence detect bit for the other controller is not
working. This controller does not "see" another
controller in the enclosure, yet it can communicate
successfully with the Trifid on the other controller.
This error is logged only once per power on.
N
he "other controller" interrupt seems to be broken.
The timer interrupt fired multiple times with new
communication messages but no "other controller"
interrupts were present. This error is logged only
once per power on.
N
An attached disk unexpectedly disconnected during
a disk data transfer. This is informational, not an
error.
N
A device was successfully transitioned to the down
state in response to user request.
N
The data unavailable condition was triggered. This
is due to multiple failed, down, or missing drive(s).
The condition persists as a warning until less than 2
drives and down, failed, or missing.
N
here is insufficient disk space for rebuild to execute.
This may be due tothe mix of disk sizes on the
subsystem. This message follows the message and
may follow the REBUILD message.
N
ebuild has been automatically restarted due to disk
failure or removal. Thismessage follows the
message.
N
ab Instrumentation Only.
N
ab Instrumentation Only.
N
ebuild has been cancelled either automatically or by
command. The subsystemautomatically cancels
rebuild if it needs to restart rebuild due to a
diskaddition, a LUN deletion, or a LUN format.
This message follows the message and may be
followed by another message.
N
host command has changed rebuild I/O priority
relative to host I/Os. Thismessage follows the
message.
N
This error code indicates the system state change
consisting of a hot plug removal. This event occurs
for drives that are not volume set members when
they are removed. The device number field is not

Advertisement

loading