Download Print this page

HP StorageWorks 7100 - Virtual Array Appendix page 19

Appendix a. disk array controller log
Hide thumbs Also See for StorageWorks 7100 - Virtual Array:

Advertisement

Event
Event
Number
Name
(dec/hex)
381/0x17d
LCC Installed
382/0x17e
LCC Removed
383/0x17f
DDM failed image disks
384/0x180
Battery charger firmware
downloader status
385/0x181
Failure in TWSI Driver module
386/0x182
VSC7130 chip failed
387/0x183
Internal drive inserted
388/0x184
Internal drive removed
389/0x185
Internal drive requesting port
bypass
390/0x186
Internal drive has stopped
requesting port bypass
391/0x187
Internal drive is indicating a
fault
392/0x188
Internal drive is no longer
indicating a fault
393/0x189
No GBIC Installed
394/0x18a
GBIC of type MOD DEF 4
Installed
395/0x18b
GBIC of type Mod Def 4
Removed
396/0x18c
GBIC Transmit Fault
397/0x18d
GBIC no longer indicating
Transmit Fault
398/0x18e
GBIC Receive Signal Lost
399/0x18f
GBIC no longer indicating
Receive Signal Lost
400/0x190
Non-Mod Def 4 GBIC
Installed
401/0x191
Non-Mod Def 4 GBIC
Removed
402/0x192
GBIC EEPROM has failed
403/0x193
JBOD FC Signal Detected
404/0x194
JBOD FC Signal Lost
Predictive
Suspected
Maintenance
Components
Implication
Y
Ignore - Operator
LCC, Back End
Activity
FC Port,
Controller
Y
Ignore unless no
LCC, Back End
Operator activity
FC Port,
Controller
Y
Ignore unless no
disk drives
Operator activity
Y
battery charger
Y
Controller,
battery, power
supply,
midplane
Y
VSC7130
Signal Detect /
Port Bypass
Control chip
Y
Disk internal to
the controller
enclosure
Y
Disk internal to
the controller
enclosure
Y
Disk internal to
the controller
enclosure
Y
Disk internal to
the controller
enclosure
Y
Disk internal to
the controller
enclosure
Y
Disk internal to
the controller
enclosure
Y
GBIC port
Y
GBIC port
Y
GBIC port
Y
GBIC port
Y
GBIC port
Y
GBIC port
Y
GBIC port
Y
GBIC port
Y
GBIC port
Y
GBIC
Y
JBOD Port
Y
JBOD Port
Description
is ErrEnR2. The tenth byte is ErrDR2.
N
This error code indicates the system state change
consisting of an LCC hot plug insertion. The device
number of the drive added appears in this change
record. A device number consisting of the
controller serial number followed by a 0 indicates
that the device number has not yet been assigned.
N
This error code indicates the system state change
consisting of an LCC hot plug removal. The device
number of the lcc removed appears in this change
record. A device number consisting of the
controller serial number followed by a 0 indicates
that the device number has not yet been assigned.
N
This error code indicates the system could find a
usable image disk to reload NVRAM from at system
start up.
N
This event is used to report status related to the
battery charger firmware download process. See the
extended event info field for the actual status.
Y
2C_DRIVER_FAILURE This error indicates that an
attempt to communicate with a two-wire serial
device has failed, possibly after multiple retries.
Y
The VSC7130 chip used for FC signal detect and
port-bypass control has suffered a hardware failure.
There is a VSC7130 for the host port and one for the
JBOD port. This will result in the controller being
failed. See extended information for which 7130
failed.
N
An internal disk has been inserted into the
enclosure.
N
An internal disk has been removed from the
enclosure.
N
An internal disk is requested that its FC port be
bypassed.
N
An internal disk has stopped requesting that its FC
port be bypassed.
N
An internal disk is indicating that it is faulted.
N
An internal disk is no longer indicating that it is
faulted.
N
No GBIC is installed on this controller
N
A GBIC has been inserted on this controller
N
A GBIC has been removed from this controller
N
The GBIC is indicating a transmit fault
N
The GBIC is no longer indicating a transmit fault
N
The GBIC is indicating that the no receive signal is
present
N
The GBIC is no longer indicating that the no receive
signal is present
Y
A non-Module Definition 4 type GBIC has been
installed. This GBIC type is not supported and will
be disabled. This GBIC will also be marked as
failed.
N
A non-Module Definition 4 type GBIC has been
installed. This GBIC type is not supported but will
be used anyway.
Y
Unable to communicate with the EEPROM on the
GBIC. The EEPROM must be failed.
N
An FC signal is now detected on the JBOD port.
N
An FC signal is no longer detected on the JBOD

Advertisement

loading