Event
Event
Number
Name
(dec/hex)
273/0x111
Disk Drive Added To Disk Set
274/0x112
Disk Drive Removed
275/0x113
Disk Drive Deleted From Disk
Set
276/0x114
Logical Unit Created
277/0x115
Logical Unit Deleted
278/0x116
Logical Unit Modified
279/0x117
Disk Set Attached
280/0x118
Reset To Clear VSC7130
interrupt
281/0x119
Unable To Recreate Memory
Error
282/0x11a
Memory Error Not Recovered
With Redundancy
283/0x11b
Memory Error Recovered With
Redundancy
284/0x11c
Uncorrectable Memory Error
285/0x11d
Correctable Memory Error
Predictive
Suspected
Maintenance
Components
Implication
Y
Ingore - Operator
None
activity
Y
Ignore unless no
Disk Drive,
Operator activity
Back End SCIS
Bus, Controller
Y
Ignore - Operator
None
activity or
assocaited errors
Y
Ignore - Operator
None
or host activity
Y
Ignore - Operator
None
or Host activity
Y
Ignore - Host
None
Activity
Y
Ignore - Operator
None
activity
Y
Ignore - unless
VSC7130 - on
repeated
controller
Y
Ignore
None
Y
> 1 in 6 mo.
SIMM,
Controller,
Backplane
Y
Ignore - See
None
accompanying
errors
Y
> 1 in 6 months
Controller,
per controller
SDRAM,
midplane
Y
See correctable
SDRAM,
rate assocaited
controller,
with usage page
midplane
Description
by a 0 indicates that the device number has not yet
been assigned.
N
This error code indicates the system state change
consisting of the addition of a new volume set
member. This occurs only when a drive that was
not previously a member becomes a member. It
does NOT occur then down, failed, or missing
drives are returned to good standing. The device
number of the drive added appears in this change
record.
N
This error code indicates the system state change
consisting of a hot plug removal. This event occurs
for volume set members only. The device number
of the drive removed appears in this change record.
A device number consisting of the controller serial
number followed by a 0 indicates that the device
number has not yet been assigned.
N
This error code indicates the system state change
consisting of the deletion of a new volume set
member. This occurs only when a drive that was
previously a member becomes a non-member. The
drive may or may not be present in the subsystem at
the time. The device number of the drive added
appears in this change record.
N
This error code indicates the system state change
consisting of the creation of a new SCSI LUN. This
change occurs only if LUN creation succeeds.
N
This error code indicates the system state change
consisting of the deletion of an existing SCSI LUN.
This change occurs only if LUN deletion succeeds.
N
This error code indicates the system state change
that occurs when an existing LUN is modified. This
change occurs only if LUN modification succeeds.
N
This error code indicates the system state change
consisting of attachment to a new volume set has
occurred. This occurs after every format subsystem
and whenever a power on or reset occurs while the
controller is not attached to a volume set. In some
cases the currently attached volume set may be
empty.
Y
This error code indicates that VSC7130 interrupt
could not be cleared. The controller was reset in an
effort to clear the interrupt.
N
This error code indicates that the system
experienced a memory error and was unable to
recreate the failed memory accesses. An excessive
number of un-reproducible memory errors will
result in a controller failure.
Y
This error code indicates that the system
experienced a unrecoverable error that could not be
recovered via redundant memory. This will cause
information loss if the error occurs in non-redundant
NVRAM memory.
N
This error code indicates that the system
experienced a unrecoverable error that could be
recovered via redundant memory or a controller
reset
Y
This error code indicates that the system
experienced a uncorrectable shared-memory error.
The two word queue entry found in the shared-
memory controller error queue will be placed in the
event extended info area. After all entries currently
in the queue have been processed, the subsystem
will undergo a short reset at which time an attempt
will be made to correct the error using the mirrored
copy of memory (if available).
Y
This error code indicates that the system
experienced a correctable shared-memory error.
The two word queue entry found in the shared-
memory controller error queue will be placed in the
event extended info area. After all entries currently

Advertisement