Fiber Optic Port Leds; Table 6. Leds For The 10/100Base-Tx Twisted Pair Ports On The At-8524Poe Switch - Allied Telesis AT-8500 Series Installation Manual

At-8500 series layer 2+ fast ethernet switches
Table of Contents

Advertisement

Chapter 1: Overview
Fiber Optic Port
LEDs
34
Table 6. LEDs for the 10/100Base-TX Twisted Pair Ports on the
AT-8524POE Switch (Continued)
LED
State
Mode - DC
OFF
Steady
Green
Steady
Amber
Flashing
Amber
Mode - POE
OFF
Green
Steady
Amber
Flashing
Amber
This section applies to the AT-8516F/SC switch. The fiber optic ports on
an AT-8516F/SC switch have two LEDs, labeled L/A and D/C. The LEDs
Description
Indicates that the port has not established a
valid link with its end node.
Indicates that the port is operating in full
duplex mode.
Indicates that the port is operating in half
duplex mode.
Indicates that the port is operating in half
duplex mode and that data collisions are
occurring on the port.
Indicates that the device connected to the
port is not a powered device and does not
require PoE.
Indicates that the end node is a powered
device and that the port is providing power
to it.
Indicates that the port experienced a
problem providing PoE to the end node. For
further information, refer to Chapter 3,
"Troubleshooting" on page 77.
Indicates that the port is connected to a
powered device but that providing power to
it would exceed the maximum PoE power
budget of the switch. For further
information, refer to Chapter 3,
"Troubleshooting" on page 77.