Hp netserver lxr pro8 post and beep codes
Hide thumbs Also See for D7171A - NetServer - LPr:

Advertisement

Actions You Can Take
Enter the SETUP menu by pressing the F2 key during POST.
Set the system configuration to your needs. Save the new
1.
configuration, and exit SETUP.
If the problem persists, the RTC on the system board is
2.
not working. Call your HP Service Representative for
further assistance. (This error will occur when the
user flashes a new BIOS into the system, as the
CMOS area is cleared by the flash utility. Follow the
above instructions to fix CMOS checksum.)
260 System timer error
Testing of the system timer during POST failed.
Actions You Can Take
Reboot the system and see if the error persists. If the error
occurs again, the system board must be replaced. Call your HP
service representative for further assistance.
270 Real time clock error
This error will occur if the RTC chip on the system board is not
working.
Actions You Can Take
Reboot the system and see if the error persists. If the error
persists, the system board must be replaced. Call your HP service
representative for further assistance.
271 Check date and time settings
The server has lost its date and time settings.(This error will
occur when the BIOS is flashed using the flash update
utility in the Navigator CD-ROM.)
Actions You Can Take
Enter the system SETUP menu by pressing the F2 key
1.
during POST.
Set the system date and time, save the changes, and exit
2.
Setup.
If the system loses its date and time frequently, the RTC may not
be working correctly. The system board may have a problem. Call
your HP service representative for further assistance.
280 Previous boot incomplete -- default configuration
used.
This error will be displayed if the system was rebooted midway

Advertisement