Hp netserver lxr pro8 post and beep codes
Hide thumbs Also See for D7171A - NetServer - LPr:

Advertisement

This error should not occur, as the HP NetServer LXr Pro8 has no
keyboard lock switch.
220 Monitor type does not match CMOS -- run Setup
This error may not occur on the HP NetServer LXr Pro8, as the
system supports standard VGA with additional higher resolutions.
230 System RAM failed at offset: xxxx
This error will occur if the system RAM test failed during the
diagnostic mode memory test.
Actions You Can Take:
Replace the DIMM that is reported as failed.
231 Shadow RAM failed at offset: xxxx
This error will occur if the shadow RAM fails the test. Shadow
RAM is a portion of the memory which is used to improve the
system performance during access to the option ROMs.
Actions You Can Take
If the error persists, replace the DIMM that failed.
232 Extended RAM failed at offset: xxxx
This error will occur if the RAM test above 1M of memory failed.
Actions You Can Take
If the error persists, replace the DIMM that failed.
250 System battery is dead -- replace and run Setup
If this error is displayed, the system's real time clock chip may
not be working correctly.
Actions You Can Take
Enter the system SETUP menuby pressing the F2 key
1.
during POST.
Set the system date and time, save the changes, and exit
2.
Setup.
If the error persists, the RTC on the system board is faulty. Call
your HP service representative for further assistance.
251 System CMOS checksum is bad -- Default
configuration used
If this error is displayed, the system configuration is corrupt and
a default configuration has been used.