Universal rack mount kit installation
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:

Advertisement

Installing the Switch in a Rack Using the SAN Switch Universal Rack Mount Kit
Note:
is installed in the HP System/e rack. The plenum is not needed if the switch is installed
in an HP 9000 Series or comparable EIA rack.
Verify that the plenum (part number A7346-00001) is preinstalled on the SAN Switch
2/8 before proceeding. The plenum is required for the SAN Switch 2/8 rack mount
only, as it allows air to dissipate at the rear of the rack, preventing overheating.
If the plenum is not preinstalled on the SAN Switch 2/8, refer to the HP StorageWorks
SAN Switch 2/8 Version 3.1.x Installation Guide for complete plenum installation
instructions.
Figure 8: Assembling the inner rails on a SAN Switch 2/8 with plenum
10
Addendum Pg
b. For the SAN Switch 2/8, assemble the two inner rails (one on each side)
to the switch and plenum using the appropriate number (from
#8-32 x 3/16-inch Phillips pan-head screws as shown in
The plenum is only a required part of this installation when the SAN Switch 2/8
HP StorageWorks SAN Switch 2/8|16|32 Installation Guide
step
5) of
Figure
8.