HP StorageWorks 2/16 - SAN Switch Installation Manual page 10

Universal rack mount kit installation
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:

Advertisement

Installing the Switch in a Rack Using the SAN Switch Universal Rack Mount Kit
6. For the SAN Switch 2/32 and SAN Switch 2/16, perform
Note:
2/16, and SAN Switch 2/8. The mounting holes in the inner rails are marked with 32,
16, and 8. Use the appropriately labeled mounting holes when installing the inner rails
on a switch. For example, to install the inner rails on the SAN Switch 2/32, use the
mounting holes labeled with 32.
When viewing a rack from the front, the left rails are used in the left side of the rack and
the right rails are used in the right side of the rack. The rails must match up—right inner
with right outer and left inner with left outer. Note that the SAN switch mounts in the
rack with its front, the port side, facing the back of the rack. The rear of the switch, the
AC side, faces the front of the rack.
8
Addendum Pg
Switch 2/8, perform
Caution:
Do not use any other screws other than the fourteen that are
provided. Use of any longer lengths can cause damage to internal components
The inner rails work for all three SAN switches—SAN Switch 2/32, SAN Switch
step
b.
HP StorageWorks SAN Switch 2/8|16|32 Installation Guide