Switch Diagnostics Dialog Box - HP StorageWorks SN6000 User Manual

Fibre channel switch quicktools switch management
Hide thumbs Also See for StorageWorks SN6000:
Table of Contents

Advertisement

Online—A non-disruptive test that exercises port-to-device connections for all ports on a switch that are
currently online except for TR ports, which are not included in Online Switch Diagnostics.
Offline—A disruptive test that exercises all port connections for a switch in the diagnostics state. When
you run an offline test, the switch will automatically be put into diagnostics state, and the switch will not
be returned to its original state until the Switch Diagnostics dialog box is closed. A disruptive switch
reset must be done at that time to return the switch to its original state.
Connectivity—A disruptive test that exercises all port and inter-port connections for a switch in the
diagnostics state. When you run a connectivity test, the switch will automatically be put into diagnostics
state, and the switch will not be returned to its original state until the Switch Diagnostics dialog box is
closed. A disruptive switch reset must be done at that time to return the switch to its original state. The
two types of connectivity tests are internal loopback and external loopback.
Figure 36

Switch Diagnostics dialog box

To test a switch:
1.
Open the faceplate display of the switch to be tested.
2.
Open the Switch menu and select Switch Diagnostics, and then select Online Switch Diagnostics or
Offline Switch Diagnostics to open the Switch Diagnostics dialog box.
3.
Select the test type from the drop-down list.
If you selected the Offline Switch Diagnostics option, your test type options, Offline and
CAUTION:
Connectivity, will disrupt traffic. When you run an Offline or Connectivity test, the switch will be put
into diagnostics state for you, and the switch will not be returned to its original state until you close
the Switch Diagnostics dialog box. A disruptive switch reset must be done at that time to return the
switch to its original state. If you selected the Online Switch Diagnostics option to run the online
switch test and there are no ports with an active login at that time, the test will return immediately
with a Passed status.
4.
Enter a frame size in the Frame Size field.
5.
Enable or disable the Terminate Test Upon Error option.
6.
Select a Loop Count option. The Loop Forever option runs the test until you click Stop Test. The Loop
Count option runs the test the number of times you entered in the Loop Count field.
7.
Select the default test pattern or enter a user-defined (hexadecimal) test pattern.
HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide