8.
Click Start Test to begin the next test, or click Close to close the Switch Diagnostics dialog box.
Observe the results in the Test Results area. If the Test Status field in the Test Results area indicates
Failed, note the Test Fault Code displayed in the Switch Information data window and contact Tech
Support.

Archiving a switch

You can create an .XML archive file containing the configuration parameters. This archive file can be used
to restore the configuration on the same switch or on a replacement switch. You can also use the archive
file as a template for configuring new switches to add to a fabric.
Basically any data received by QuickTools is archived. Passwords are not archived. Security Group secrets
are not included in the archive and must be re-configured using the CLI after a restore.
Archived parameters include:
Switch properties and statistics
IP configuration
SNMP configuration
Port properties and statistics
Name server
Date/Time and NTP settings
Alarm configuration
Zoning configuration
Nicknames configuration
Call Home parameters
User account information (but not restored)
Configured security (available only with SSL connection to the switch).
RADIUS Server information (available only with SSL connection to the switch)
NOTE:
Security features must be configured using the CLI or Enterprise Fabric Management Suite. See the
HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide for information about the
command line interface, and HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Enterprise
Fabric Management Suite User Guide for information about Enterprise Fabric Management Suite..
To archive a switch:
1.
Select Switch > Archive.
2.
In the Save dialog box, enter a file name.
3.
Click Save.

Restoring a switch

Restoring a switch loads the archived switch configuration parameters to the switch. The administrative
state of the switch must be set to Offline using the Switch Properties dialog box before an archive can be
used in the restore process. The switch type archive must be compatible with the switch to be restored. See
"Archiving a
switch" (page 74) for more information.