Table 27 RAID Manager error codes for Continuous Access Synchronous (SSB1 is
B901/B90A/B90B/B912/D004) (continued)
Error code
Description
(SSB2)
C31D
The P-VOL is being formatted.
C31E
The P-VOL is read only.
C320
The number of primary-secondary system logical paths is 0 (for example, not specified).
C321
The number of primary-secondary system logical paths is smaller than the minimum required.
C322
The DKC type of the primary system does not support Continuous Access Synchronous.
C324
The secondary system's sequence number, SSID, or CU are invalid.
C327
The pair cannot be created because the P-VOL is not available for remote copy.
C328
The track formats of the P-VOL and the S-VOL do not match.
C32A
The S-VOL is protected by the Data Retention.
C32B
The P-VOL is protected by the Data Retention.
C32C
The S-VOL is protected by the Data Retention.
C32E
A request for a Paircreate operation was received. The command was rejected because the specified
secondary system is an unsupported product.
C32F
The number of P-VOL cylinders is not the same or smaller than the number of S-VOL cylinders.
C330
The P-VOL's volume capacity is not equal to the S-VOL's.
C332
S-VOL cache is unavailable.
C333
S-VOL DFW is disabled.
C335
The S-VOL is the P-VOL of Continuous Access Synchronous.
C336
The S-VOL includes PIN data.
C337
The S-VOL is in reserve status.
C338
Copy pair cannot be created because of the either of the following reasons.
The S-VOL is in the intervention-required condition, protected, or unusable status.
The S-VOL is the S-VOL or Reserved volume of Business Copy, Reserved volume of Auto LUN, or the
volume of Continuous Access Journal pair.
C33A
A request for a Paircreate operation was received. The command was rejected because the secondary
system is a not supported by Continuous Access Synchronous.
C33B
The corresponding volume cannot be specified as an S-VOL because the volume is used as another pair's
S-VOL.
C33C
A request for a Paircreate operation was received. The command was rejected because the specified S-VOL
was not mounted.
C33E
The pair cannot be created because the S-VOL is not implemented or is blocked (DEV NOT READY status).
C33F
The corresponding volume cannot be specified as an S-VOL because the volume is already specified as
Continuous Access Synchronous pair volume.
C35C
The P-VOL is not accessible.
C370
The number of paths is fewer than the required minimum number following a path failure or because an
invalid path was specified.
C371
The process which is performed after the copying process of Auto LUN in the S-VOL is in progress. Retry
the operation several minutes later.