Table 27 RAID Manager error codes for Continuous Access Synchronous (SSB1 is
B901/B90A/B90B/B912/D004) (continued)
Error code
Description
(SSB2)
B9BD
The DKC LDEV configuration might have been changed while starting RAID Manager. Restart RAID Manager.
B9C0
The source of the command device has run out. In LUN Manager, set the command device to OFF, then to
ON.
C162
A request for a Pairresync operation was received. The command was rejected because the pair was not
in the Suspend status.
C184
A request for a Pairsplit-S operation was received. The command was rejected because the status change
of the S-VOL failed.
C189
A request for a Pairsplit-S operation was received. The command was rejected because the pair status was
invalid.
C18A
A request for a Pairsplit-S operation was received. The command was rejected because the corresponding
volume or group was changing status.
C194
The pair cannot be split because the S-VOL pair status was in transition.
C195
A request for a Pairsplit-r operation was received. The command was rejected because the pair status was
already PSUS or PSUE.
C198
Pair split cannot be executed because the group includes no pair that can be split.
C199
A request for a Pairsplit-r operation was received. The command was rejected because the corresponding
volume or group was changing status.
C1BE
The pair's status cannot be changed during the power-on processing of the DKC.
C21 1
The command was rejected because the specified volume is used for a P-VOL.
C212
The command was rejected because the specified volume is used for an S-VOL.
C214
The command was rejected because the secondary system is not registered, or the registered information
is invalid.
C215
The command was rejected because an internal logical error has occurred.
C218
The command was rejected because the pair status is invalid.
C21A
The command was rejected because the P-VOL status is not PSUS, PSUE, or PDUB.
C21C
The command was rejected because the secondary system is not registered, or the registered information
is invalid.
C22A
The command was rejected because the pair release is executed to the volume other than P-VOL.
C22C
The command was rejected because the volume status is SMPL.
C22D
The command was rejected because the specified volume is the volume other than the P-VOL.
C22E
The command was rejected because the pairsplit command specifying -P option (write protection of P-VOL)
was issued to a volume whose status is not PAIR.
C233
The command was rejected because the S-VOL status is SMPL.
C234/C235/
The command was rejected because an internal logical error has occurred.
C236/C237
C238
The command was rejected because the specified volume is the volume other than P-VOL.
C239
The command was rejected because the pair resync was operated to the volume which status is other than
PSUS, PSUE, or PDUB.
C23A
The command was rejected because an internal logical error has occurred.
C23B
The command was rejected because the volume status is SMPL.