Add Journal - HP StorageWorks P9000 User Manual

Continuous access journal for mainframe systems user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

2.
In the tree, double-click Registered, then double-click the desired LDKC which displays below
Registered. Associated EXCTGs display in the tree below the selected LDKC.
3.
Select the desired EXCTG in the tree. Associated storage systems then display in the tree.
4.
Select the storage system you want.
The storage systems in the EXCTG display as shown in the following figure.
Fields in the storage system list are described in the following table.
Item
JNL
Mirror ID
Attribute
Status
JNL
To determine if a pair in an Active journal is split, navigate to the Journal Operation window and
check the status of the journal. If a pair is split, the Journal Operation window displays the status
of the journal as Active(Warning).

Add Journal

Item
JNL of the local DKC
is used in check box
ON
DKC 1 to DKC 4
S/N
LDKC
Description
Journal numbers. A journal number is a two-digit hexadecimal number.
Mirror ID of a journal.
The attribute of a journal
: A master journal.
: A restore journal.
Status of a journal.
Journal numbers. A journal number is a two-digit hexadecimal number.
Description
Specify whether to register journals of the supervisor storage system by selecting the check box
of far left of DKCs (DKC 1 to DKC 4). The check box is selected on DKC 1 by default. Clear
this check box if you do not want to register journals of the supervisor storage system.
Represent four storage systems. Note that even if the extended consistency group uses more
than four storage systems, the dialog box shows only up to the fourth storage system.
Specify the serial number of a storage system.
If journal of the local DKC is used in check box ON is selected, the serial number of the supervisor
storage system is already specified and unchangeable.
If journal of the local DKC is used in check box ON is cleared, you cannot specify the serial
number of the supervisor storage system. You cannot set the same serial number to DKC 1
through DKC 4.
The LDKC number of a storage system.
EXCTG Operation window 193

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks p9500

Table of Contents