7.
Click Set when finished.
8.
See the Preview list to check the settings that you have made.
If you want to modify a setting, select and right click the setting in the Preview list and
then select Modify.
If you want to cancel a setting, select and right click the setting and then select Cancel.
If necessary, repeat steps from 2 to 6 to specify volumes that should be deleted from other
journals.
9.
Click Apply to apply the settings. If an error occurs, the error code appears in the rightmost
column of the Preview list. To view detailed information about the error, right click the error
code and select Error Detail.

Delete a journal

Journals can be deleted from either storage system.
Prerequisite information
When all mirrors in the journal are in the Initial status, you can delete the journal.
Master and restore journals cannot be deleted.
To delete a journal
1.
In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal Z >
Journal Operation. The Journal Operation window displays.
2.
Click
3.
From the tree, click Registered. Journals display in the list on the right.
4.
Select and right-click the desired journal. Only one journal can be selected. Click Journal >
Delete Journal from the menu that displays.
5.
See the Preview list to check the settings that you have made.
If you want to cancel a setting, select and right click the setting and then select Cancel.
6.
Click Apply to apply the settings. If an error occurs, the error code appears in the rightmost
column of the Preview list. To view detailed information about the error, right click the error
code and select Error Detail.
7.
The deleted journal displays in the Preview list. You can cancel the operation by clicking the
Cancel. To complete the deletion, click Apply.

Logical path maintenance

This section provides the following:
Modifying Path Volume Thresholds
Deleting Logical Paths
Deleting the Continuous Access Journal Z Relationship

Modify data-transfer time threshold

You can modify the threshold for data transfer to complete. If the threshold value is reached, the
transfer is flagged as failing by the system.
100 Maintaining the system