HP StorageWorks P9000 User Manual page 149

Continuous access journal for mainframe systems user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

4.
After Business Copy Z has completed the split operations, Continuous Access Journal Z resumes
the suspended restore operation of the restore journal.
CAUTION:
When using the At Time Split function when combining Continuous Access Journal
Z with Business Copy Z, observe the following cautions:
Configure Business Copy Z pairs on all Continuous Access Journal Z S-VOLs. All Business
Copy Z pairs that are in conjunction with Continuous Access Journal Z S-VOLs must be
registered in the same Business Copy Z consistency group. Consistent backup operations
cannot be performed if Business Copy Z pairs are set to a portion of Continuous Access Journal
Z pairs or Business Copy Z pairs that are in conjunction with Continuous Access Journal Z
S-VOLs are registered to separate Business Copy Z consistency groups. In addition, if multiple
journal groups are registered in one Business Copy Z consistency group, consistent backup
operations cannot be performed on the Business Copy Z
that the multiple journal groups are registered in one Business Copy Z consistency group.
When you execute split operation, the Continuous Access Journal Z pair status must be duplex,
and the Business Copy Z pair status must be either duplex or pending. If the status of the
Continuous Access Journal Z pair or the Business Copy Z pair is suspended due to a failure,
the journal data which was created before the split time may not be restored to the Business
Copy Z T-VOL after the split operation has been completed. The split time and the actual
starting time of the split operation are not necessarily the same. The starting time of the split
operation will delay depending on the amount of journal data stored in the journal volume at
the split time. For example, if journal data that needs one hour to be completely restored is
stored at the split time, the starting time of the split operation will delay for one hour.
Even if the specified timeout period has passed from the split time, journal data with the time
stamp later than the split time may not be detected due to some reason such as a lot of journal
data stored in the journal volume. If the journal data with such a time stamp cannot be detected,
the split operation of the Business Copy Z pair executes after the specified timeout period.
Because the time out value is variable, set the value according to your environment. The default
time out value is 6 hours. For details on how to specify a timeout value, see the manual of
Business Continuity Manager.
Figure 29 Configuration of multiple journal groups registered in One Business Copy Z consistency
group
If you use the At-Time Split function when combining Continuous Access Journal Z with Business
Copy Z, note the following:
The specified split time is enabled even after the split operation has been executed on Business
Copy Z pair. When you execute split operation again on Business Copy Z consistency group
that has been split before, specify the split time after deleting the split time registered before.
In cascading configuration of Continuous Access Journal Z and Cnt Ac-S Z, the At-Time Split
function cannot be used for Business Copy Z pairs in conjunction with Continuous Access
Using At-Time Split function when combining Continuous Access Journal Z with Business Copy Z 149
T-VOLs.Figure 29 (page 149)
shows

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks p9500

Table of Contents