Lenovo J200 Hardware Maintenance Manual page 67

Hardware maintenance manual
Table of Contents

Advertisement

Diagnostic Error Code
005-036-XXX
Video Register error
005-038-XXX
System BIOS extension failure
005-040-XXX
Video IRQ failure
005-195-XXX
Video Test aborted by user
005-196-XXX
Video test halt, error threshold exceeded
005-197-XXX
Video test warning
005-198-XXX
Video test aborted
005-199-XXX
Video test failed, cause unknown
005-2XX-XXX
005-3XX-XXX
Video subsystem error
006-000-XXX
Diskette interface Test Passed
006-0XX-XXX
Diskette interface error
006-195-XXX
Diskette interface Test aborted by user
006-196-XXX
Diskette interface test halt, error threshold
exceeded
FRU/Action
1. Video card, if installed
2. System board
1. Video card, if installed
2. System board
1. Video card, if installed
2. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Re-run test
3. Replace the component called out in
warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Flash the system and re-test. See "Flash
update procedures" on page 243
3. Go to "Undetermined problems" on page
81
1. Go to "Undetermined problems" on page
81
2. Flash the system and re-test. See "Flash
update procedures" on page 243
3. Replace component under function test
1. Video card, if installed
2. System board
No action
1. Diskette drive Cable
2. Diskette drive
3. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter 7. Symptom-to-FRU Index
61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents