Download Print this page

Allied Telesis 86222-25 Release Note page 26

Patch for rapier switches and ar800 series modular switching routers

Advertisement

26
PCR: 01288
Module: SWI
When a switch port was forced to half duplex mode and the link partner
was forced to full duplex mode, it was possible for the switch to enter a state
where it was unable to transmit packets. This issue has been resolved.
Features in 86222-10
Patch file details for Patch 86222-10 are listed in Table 15.
Table 15: Patch file details for Patch 86222-10.
Base Software Release File
Patch Release Date
Compressed Patch File Name
Compressed Patch File Size
Patch 86222-10 includes all issues resolved and enhancements released in
previous patches for Software Release 2.2.2, and the following enhancement:
PCR: 01264
Module: SWI
Some switch chip register settings have been optimised to improve the
provision of CoS with the newer revision of switching silicon.
Features in 86222-09
Patch file details for Patch 86222-09 are listed in Table 16.
Table 16: Patch file details for Patch 86222-09.
Base Software Release File
Patch Release Date
Compressed Patch File Name
Compressed Patch File Size
Patch 86222-09 includes all issues resolved and enhancements released in
previous patches for Software Release 2.2.2, and the following enhancements:
PCR: 01189
Module: STP, SWI
A new feature, STP forwarding, has been added. STP forwarding can be
enabled and disabled using the commands:
ENABLE SWI STPFORWARD
DISABLE SWI STPFORWARD
When STP forwarding is enabled, all STP forwarding is ignored and all
BDPUs received on a port are forwarded on all other ports.
Patch Release Note
Network affecting: No
86s-222.rez
29-Nov-2001
86222-10.paz
295536 bytes
Network affecting: No
86s-222.rez
27-Nov-2001
86222-09.paz
295444 bytes
Network affecting: Yes
Patch 86222-25 for Software Release 2.2.2