Elation 60TM User Manual
Elation 60TM User Manual

Elation 60TM User Manual

Elation professional work light user manual

Advertisement

Quick Links

Design Wash LED 60
Elation Professional
6122 S Eastern Ave
Los Angeles, Ca 90040
www.elationlighting.com
Rev. 10/06/2009 – visage
Version 1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 60TM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elation 60TM

  • Page 1 ™ Design Wash LED 60 Elation Professional 6122 S Eastern Ave Los Angeles, Ca 90040 www.elationlighting.com Rev. 10/06/2009 – visage Version 1.1...
  • Page 2 Design Wash LED 60™ ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 3: Table Of Contents

    12. DMX Channel Traits…...….…………………………………………………………….. 36 a. DMX Channel Values…………………………………………………………… 37 13. Error Codes………………………………………………………………………………. 39 14. Cleaning and Maintenance……………………………………………………………… 40 15. Photometric Data………………………………………………………………………….41 16. Dimensional Drawings………………………………………………….……………….. 42 17. Circuit Schematic………...………………………………………………………………. 43 18. Warranty……………………………………………………………………………………44 19. Technical Specifications…………………………………………...………….………… 46 ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 4: General Information

    You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service related issue please contact Elation Professional Service Hours are Monday through Friday 8:00 a.m. to 5:00 p.m. Pacific Standard Time.
  • Page 5: Warranty Registration

    Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord. Please be aware that damages caused by manual modifications to the device are not subject to warranty. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 6: Safety Instructions

    9. Installation should only be performed by qualified and certified personal. Important Notice: Damages resulting from the disregard of safety and general user instructions found in this user manual are not subject to any warranty claims. ©Elation Professional, Los Angeles Ca. ™ is an extremely sophisticated piece ™...
  • Page 7: Features

    • 7 built-in programs accessed via DMX-controller or manually • Built-in DMX recorder - via the control board or external controller, up to 64 scenes can be saved and then can be run in Stand Alone or sound activated. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 8: General Guidelines

    Do not permit operation by persons not qualified for operating this type of theatrical fixture; most damages are the result of operations by nonprofessionals. Please use the original packaging to transport the fixture in for service. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 9: Fixture Overview

    9. Enter Button 10. Control Board Assembly 11. Cooling/Fan Assembly 12. 3-Pin DMX Output 13. Battery On/Off Button 14. 3-Pin DMX Input 15. Fuse Holder 16. Power Cord 17. 5-Pin DMX Output 18. 15-Pin DMX Input ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 10 11. Cooling /Fan Assembly – The back of the head consist of the fan and cooling fin assembly. To prevent the fixture from overheating, never block the back of the head during normal operation. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 11 17. 5-Pin DMX Output Jack – This jack is used to send an incoming DMX signal to the next fixture in the DMX chain via a female, 5-pin XLR jack. 18. 5-PIN DMX Input Jack – This jack accepts an incoming DMX signal via a male, 5-pin XLR jack. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 12: Mounting And Installation

    Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217 for proper installation in Europe To ensure proper installation, only qualified staff should attempt installation. ©Elation Professional, Los Angeles Ca. is fully operational in two different mounting positions, hanging www.ElationLighting.com...
  • Page 13: Mounting Points

    Improper installation can result in bodily injury. CAUTION! Be sure a qualified electrician performs all electrical connections. Be sure to complete all rigging and installation procedures before connecting the main ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 14: Securing

    The fixture provides a built-in rigging point for a safety cable on the hanging bracket as illustrated above. Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 15: Understanding Dmx

    120 ohms; this cable is designed for DMX transmission and may be purchased from your Elation dealer or at most professional lighting retailers. Your cables should be made with a male and female XLR connector on either end of the cable. Also, remember that a DMX line ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 16 Always be sure daisy chain your in and out data connections, never split or “Y” your DMX connections unless you are using an approved DMX splitter such as the Elation Opto Branch 4™ or DMX Branch/4™. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 17: Dmx Terminator

    All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 18 The DMX controller is switched off or defective. The DMX cable or connector is defective. A DMX terminator has been inserted into the last fixture in your DMX chain. ©Elation Professional, Los Angeles Ca. ™ will automatically detect whether a DMX...
  • Page 19: Fixture Menu

    UP or DOWN buttons to change the function. Once your changes are made tap the ENTER button yet again to lock the change in the system menu. To exit without making any changes tap the MENU button. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 20 High Fans Speed Low Fans Speed Display Setting Shutoff Time Temperature C/F Celsius Fahrenheit Initial Effect PAN…… Reset Default ON/OFF ©Elation Professional, Los Angeles Ca. A001~AXXX PAN…… Slave1,Slave2,Slave3 Master / Alone Master / Alone XXXX(Hours) XXXX(Hours) XXXX(Hours) Password=XXX ON/OFF XXX C˚ / F˚...
  • Page 21: Function Mode

    8.1.1 “Set DMX Address” - DMX address setting – This function is used to set or adjust the fixture’s starting DMX address. Every device controlled by DMX has to have a ©Elation Professional, Los Angeles Ca. PAN =XXX Password=XXX PAN=XXX...
  • Page 22 Step-Time. 8.1.5 Music control This function is similar to the “Auto Program” described in the previous section with the exception that this function will advance the built-in program via sound. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 23: Temperature Info

    • Enter Password • Press enter to confirm. • Press the Mode/Esc-button to return to the main menu. 8.2.2. Temperature Info. This function will display the internal head temperature of the fixture in real time. The ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 24: Software Version

    Down buttons to turn this function On or Off. Press the Enter button to accept the change or the Mode button to cancel and return to the main menu. This function is “OFF” by default. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 25 Speed 3: includes a faster Pan speed. Pan speed is 0.5 seconds faster than original Design Spot 250. Tilt speed will be the same as speed 2. Mic Sensitivity – This function makes the internal microphone more or less ©Elation Professional, Los Angeles Ca. ™ ™...
  • Page 26 LCD will remain on before it turns off. This function is disabled as default. 8.4.5 Temperature C/F – This function changes the temperature the unit will display from either Celsius or Fahrenheit. Celsius is set as default. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 27 050 and must be entered each time the calibration menu function is entered. Because calibration is an extremely delicate procedure instruction on performing this action are left out of this manual. For a first time calibrator, please contact our ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 28 Pre-programmed scenes can be transmitted to the fixture via any DMX compliant controller. This function allows those scenes to be stored in to the fixture’s built-in memory and then subsequently used to create the user-defined programs. ©Elation Professional, Los Angeles Ca. ™ features an integrated DMX www.ElationLighting.com...
  • Page 29: Dmx Addressing

    4. “Address via DMX” is the function that turn the RDMX function on and off. Press ENTER and be sure the function is turned on. 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 30: Controller Settings

    420, set channel 1 to a value of “7,” channel 2 to "8" and channel 3 to "164" (256+164=420). 4. Wait for approximately 20 seconds for the unit to complete the address reset function. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 31: Operation

    “Auto Program” submenu select “Alone”  For functionality that chases to sound: Access the “Function” menu and select the “Music Control” function, this will give you access to the “Music ©Elation Professional, Los Angeles Ca. Show Designer 2. ® www.ElationLighting.com...
  • Page 32  Be sure to use a terminator on the last fixture, especially for longer cable runs (more than a 100 feet).  For help operating in DMX mode be sure to consult the manual that was included with your DMX controller. ©Elation Professional, Los Angeles Ca. ™ Show Designer 2 or Elation ®...
  • Page 33: Working With Built-In Programs

    The values can be adjusted from 0~250. Once you achieved your desired value tap the “ENTER” button once again to automatically lock the value into the scenes memory. You can repeat the procedure for all ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 34 64 scenes. Keep in mind that a scene can only be access when it is stored inside one of the 10 available programs. Follow the procedure below to build an internal program: • Access the main menu and toggle to “Edit Programs” which is menu function 8. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 35 See section 10.1 “Stand-Alone Operation” on page 32 for proper set-up instructions. The 3 Slave groups run the Auto Program in certain time segments, as shown in the following diagram: ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 36: Dmx Channel Traits

    CHANNEL 9: Speed Control (Pan/Tilt movement, blackout selection) CHANNEL 10: Strobe (0-13Hz), Shutter close/open function + random strobe CHANNEL 11: Dimmer (Intensity) Control CHANNEL 12: Color Macros CHANNEL 13: Special (programs & motor reset) ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 37: Dmx Channel Values

    0-255 8-39 40-71 72-103 104-135 136-167 168-199 200-231 232-255 ©Elation Professional, Los Angeles Ca. PAN Movement 8bit: Pan Movement Pan Fine 16bit Fine control of Pan movement TILT Movement 8bit: Tilt Movement Tilt Fine 16bit Fine control of Tilt movement...
  • Page 38 Internal program 4 (secne25~32 of EEPROM) 180-199 Internal program 5 (secne33~40 of EEPROM) 200-219 Internal program 6 (secne41~48 of EEPROM) 220-239 Internal program 7 (secne49~56 of EEPROM) 240-255 Music Control (scene of Program 1) ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 39: Error Codes

    (sensor failed or magnet is missing) or there is a motor failure (defective motor or a defective motor IC drive on the main PCB). This error may also be displayed if the head was blocked during a reset function. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 40: Cleaning And Maintenance

    There are no user serviceable parts inside this fixture with the exception of the lamp. Please refer all other service related issues to an authorized Elation service technician. Should you decide to service the fixture yourself please order genuine Elation parts directly from Elation. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 41: Photometric Data

    Design Wash LED 60™ 15. Photometric Data: ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 42: Dimensional Drawings

    Design Wash LED 60™ DIMENSIONAL DRAWINGS: ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 43: Circuit Schematic

    Design Wash LED 60™ 17. CIRCUIT SCHEMATICS ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 44: Warranty

    United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the product only to the Elation Professional factory. All ®...
  • Page 45 ® liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product. G. This warranty is the only written warranty applicable to Elation Professional Products ® and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
  • Page 46: Technical Specifications

    Weight (net) Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. ©Elation Professional, Los Angeles Ca. 100~240v 50/60Hz Internal Voltage Taps 120V = 3.15A/250V, GMA (5x20mm fine-wire fuse)
  • Page 47 Design Wash LED 60™ ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 48 Elation Professional ® 6122 S. Eastern Ave. Los Angeles, CA. 90040 323-582-3322 / 323-832-9142 fax www.ElationLighting.com / Info@ElationLighitng.com Version 1.1...

This manual is also suitable for:

Design wash led 60

Table of Contents

Save PDF