12 ] Final Check - Brother PT-9600 Service Manual

Service manual
Hide thumbs Also See for PT-9600:
Table of Contents

Advertisement

[ 12 ] Final Check

1.
Inspection Mode Starting Procedure
The Inspection Mode is initiated by holding down the "Code", "K" and "ON/OFF" keys
simultaneously when the internal RAM is cleared while electrical power is OFF. (The display
shifts to one as shown in Fig.2 when shifting to the Inspection Mode.)
However, the error processing will be started when the solder point error occurred, and the
display shifts to one as shown in Fig.1.
Note: First, release the "ON/OFF" key and then release the "Code" and "K" keys.
1.1.
Solder Point Check
This mode checks the solder points. Operation finishes with displaying as shown in Fig.1, if
the same type of solder points is ON for more than 2 points, or no solder point is ON.
2.
Modes for Inspection
These Modes are used to perform the final inspection for the repaired products. The list
below shows the inspection modes. Make good use of these modes in classifying into the
modes to be applied and not to be applied according to the details of repairs.
Note 1: Depression of the mode selection key allows shifting to the other mode when you are
Note 2: The modes, the latter half of Note 2, are also provided in addition to the modes listed
Note 3: The following modes are used only at the replacement of main PCB: Specification
Note 4: Full Cutter Adjustment Mode ( " F " key) and Tape Control Motor Excitation-Phase
in the initial level of every mode.
below, but are not applied for the inspection: Cut Mode ( " U " key ), Print Mode 2 ( " I
" key ), Avery Control Value Display Mode ( " O " key ), Information Mode ( " P " key ),
Factory Set Mode 1 ( " T " key ), and Factory Set Mode 2 ( " Y " key ). Details of
these modes are left out as not used for the inspection operation.
Change Mode ( " 1 " key ), AC Adapter Rank Adjustment Mode ( " 2 " key ), RS I/F
Port Check Mode ( " 0 " key ), Clock Display Mode ( " Q " key ), Charge Check Mode (
" W " key ), and USB Mode ( " A " key ).
Check Mode ( " G " key) are used at the replacement of main PCB and the parts of
the cutter mechanism.