Checking Battery Back-up
If there are frequent nuisance/false alarms it may be necessary
to re-locate the device away from the source of the fumes. If for
The Alarm automatically monitors the battery every 40 seconds
some reason the alarm continues to sound without smoke or
to ensure that it is satisfactory. If it is depleted it will give a short
heat being present (due to insect infestation or contamination
beep every 40 seconds (models EI 181, EI 184 and EI 186
build-up for example) the units can be silenced by
only).
disconnecting the mains power and removing the unit (see
Before replacing the battery, check that the beeps are not due
figure 1). If cleaning the Alarm does not correct the problem it
to one of the following:
can be returned to the manufacturer for repair or replacement
(see Getting Your Alarm Serviced below).
(i) Battery snaps not connected properly.
Hush Feature
(ii) On the Optical Smoke Alarms only (EI 186/185) if the unit
beeps and the red light does not flash at the same time it
All the Smoke / Heat Alarms have a combined Test/Hush
Button to help you control nuisance false alarms.
indicates a problem with the smoke chamber – see Cleaning
the Smoke Alarm section below:
1. To cancel a false alarm, press the Test/Hush Button located
If the beeps have continued for over 20 minutes (and the other
on the cover. The Alarm will automatically switch to a reduced
causes of beeps have been ruled out – see below) the battery
sensitivity condition (very large levels of smoke from a nearby
must be replaced.
fire will override the Hush on the smoke alarms). This condition
allows unwanted alarms to be silenced for a period of
(iii) Switch off the panel voltage supply and remove the unit as
approximately 10 minutes.
shown in fig 1a. CAUTION: Do not attempt to remove the Alarm
without first releasing the tamper clip. Remove depleted battery
The unit will flash the red light every 10 seconds (instead
and replace with one of the specified 9V alkaline batteries. The
of the normal 40 seconds) to indicate the sensitivity is
alarm cannot be replaced on the mounting plate unless a
reduced. At the end of the hush period the Ionisation
battery is installed. After replacing the battery, slide on to the
Smoke Alarm (EI 181/180) and the Heat Alarms (EI 184/183)
mounting plate and then press the test button and ensure horn
will give two short beeps. The Optical Smoke Alarm (EI
sounds loudly before you turn on the panel supply. Note: Only
185/186) does not give these two beeps.
use the specified Alkaline batteries shown on the base label
On interconnected Alarms, pressing the Test/Hush Button on
(Duracell MN1604, Eveready 522 or Energizer 6LR61). We
the one sensing smoke (i.e. the one with the red light flashing
recommend that the "use by date" on the battery should still
every second) will silence all alarms. Pressing the Hush Button
have at least 2 years to go. Older batteries will give beeps
on any other Alarm will not cancel the alarm.
prematurely.
2. The unit will reset to normal sensitivity at the end of the
We recommend that the battery is replaced each year for
silenced period. If additional silenced time is required, simply
optimum performance.
push the Test/Hush Button again.
Please note: The ionisation and heat alarms (EI 180, 181,183
IMPORTANT SAFE GUARDS
and 184) give two short beeps about a second apart at the end
of the hush period (i.e. about 10 minutes after test/hush button
• When using household protective devices, basic safety
has been pressed). These two beeps should not be confused
precautions should always be followed, including those listed
with low battery beeps.
below:
Manual Testing
• Please read all instructions.
We recommend that the functioning of the battery back-up is
• Rehearse emergency escape plans so everyone at home
checked after installation and then at least yearly as follows:-
knows what to do in case the alarm sounds. Further
Turn off (or disconnect) the power at the panel (green light on
information can be obtained from the Home Office
mounting plate should be off) press the test button and ensure
Publication entitled "Smoke Detectors in the Home" (FB2) or
the horn sounds loudly for 10 seconds. (This checks the battery
from your local fire prevention officer.
back-up models EI 181, EI 184 and EI 186 only).
• NOTE: Constant exposure to high or freezing temperatures
Note: A good battery can supply the unit for over a year in
or high humidity may reduce the life of the battery.
standby (or 5 hours in alarm) without panel power.
• To maintain sensitivity to smoke, do not paint or cover smoke
In standby, with panel power, the battery can operate for up to 4
/heat alarms in any manner; do not permit any accumulation
years before the low battery beeps start – these will normally
of cobwebs, dust or grease.
12
last for over 30 days before the battery is fully depleted.
• If a unit has been damaged in any way or does not function
properly,do not attempt a repair. Return Alarm (see - Getting
CLEANING YOUR ALARM
your Alarm Serviced).
Clean your Alarm regularly, particularly in dusty areas. Use the
• This appliance is only intended for premises having a
narrow nozzle attachment of your vacuum cleaner to remove
residential type environment.
dust, insects and cobwebs from the sides and cover slots
where the smoke or heat enters. To clean the cover, wipe with a
• Smoke / Heat Alarms are not a substitute for insurance. The
damp cloth. Dry cover thoroughly with a lint free cloth.
supplier or manufacturer is not your insurer.
WARNING: Do not paint your Alarm.
• The chamber inside the Ionisation Smoke Alarms (EI
181/180) contains a small amount of radioactive material. Do
Other than the cleaning described above, no other customer
not tamper with the chamber. You may safely install and
servicing of this product is required. Repairs, when needed,
clean the Smoke Alarm following this leaflet's instructions.
must be performed by the manufacturer.
• In the United Kingdom Ionisation Smoke Alarms can be
All Alarms are prone to dust and insect ingress which can
disposed of in normal household refuse, but due to the tiny
cause false alarms or failure to alarm.
amount of radioactive material contained in the unit, no more
than one alarm per dustbin.
The latest design, materials and manufacturing techniques
have been used in the construction of our Alarms to minimize
• In the Republic of Ireland Ionisation smoke alarms should be
the effects of contamination. However it is impossible to
returned for disposal to the nearest address at the end of this
completely
eliminate
the
effect
of
dust
and
insect
leaflet.
contamination, and therefore, to prolong the life of the Alarm
you must ensure that it is kept clean so that excess dust does
Do not dispose of your Alarm in a fire.
not build up. Any insects or cobwebs in the vicinity of the Alarm
Use the Smoke / Heat Alarm Test Buttons to familiarize your
should be promptly removed.
family with the Alarm sound and to practice fire drills regularly
In certain circumstances even with regular cleaning,
with all family members. Draw up a floor plan that will show
contamination can build up in the smoke sensing chamber
each member at least 2 escape routes from each room in the
causing the alarm to sound or fail. If this happens the alarm
house. Children tend to hide when they don't know what to do.
must be returned to us for servicing or replacement.
Teach children how to escape, open windows, and use roll up
Contamination is beyond our control, it is totally unpredictable
fire ladders and stools without adult help. Make sure they know
and is considered normal wear and tear. For this reason,
what to do if the alarm goes off - see next page.
contamination is not covered by the guarantee and a charge is
PLANNING YOUR ESCAPE FOR WHEN THE
made for servicing such units.
ALARM GOES OFF
If you experience persistent false alarms, in particular
locations, due to contamination of the smoke chamber you
1. Check room doors for heat or
could consider replacing Optical Smoke Alarms (EI 186/185)
smoke. Do not open a hot door. Use
with Ionisation Smoke Alarms (EI 181/180). Ionisation type
an alternate escape route. Close
alarms are less susceptible to dust than Optical type alarms.
doors behind you as you leave.
NUISANCE ALARMS
2. If smoke is heavy, crawl out, staying
close to floor. Take short breaths, if
If there is a nuisance alarm simply press the test/hush button
possible, through a wet cloth or hold
on the Alarm to silence the unit for 10 minutes.
your breath. More people die from
smoke inhalation than from flames.
If, when the alarm goes off, there is no sign of smoke, heat or
noise to indicate that there is a fire, you should get your family
3. Get out as fast as you can. Do not
into a safe place, before you start investigating.
stop for packing. Have a prearranged
meeting place outside for all family
Check the house carefully in case there is a small fire smould-
members. Check everybody is there.
ering somewhere.
Check whether there is some source of smoke or fumes, for
example cooking fumes being drawn past the Smoke Alarm by
an extractor.
13
4. Call the Fire Brigade from a neighb
our's house. Remember to give your
name and address.
5. NEVER re-enter a burning house.
LIMITATIONS OF SMOKE HEAT ALARMS
Smoke/Heat Alarms have significantly helped to reduce the
number of fire fatalities in countries where they are widely
installed.
However independent authorities have stated that they may be
ineffective in some circumstances. There are a number of
reasons for this:
• The Alarms will not work if the mains power is off and the
back-up battery is depleted. On the EI181/184/186 alarms
the batteries should be replaced annually and when the unit
gives low battery beeps.
• Smoke/Heat Alarms will not detect fire if sufficient smoke/
heat does not reach the alarm.
Smoke/Heat may be
prevented from reaching the Alarm if the fire is too far away,
for example, if the fire is on another floor, behind a closed
door, in a chimney, in a wall cavity, or if the prevailing air
draughts carry the smoke/heat away. Installing Smoke/Heat
Alarms on both sides of closed doors and installing more
than one Smoke/Heat Alarm as recommended in this leaflet
very significantly improves the probability of early detection.
• The Alarm may not be heard.
• A Smoke / Heat Alarm may not wake a person who has taken
drugs or alcohol.
• Smoke / Heat Alarms may not detect every type of fire to give
sufficient early warning. They are particularly ineffective with:
fires caused by smoking in bed, escaping gas, violent
explosions, poor storage of flammable rags and/or liquids,
(for example petrol, paint, spirits etc), overloaded electrical
circuits, arson and children playing with matches.
• Fire Authorities (including the Home Office, UK) recommend
that both Optical and Ionisation Smoke Alarms should be
fitted for the fastest response to all types of fires.
• Smoke / Heat Alarms don't last indefinitely. For example if
there is a build up of contamination, performance will be
impaired.
The manufacturer recommends replacement of the Smoke/
Heat Alarms after 10 years as a precaution.
14
16
ACCESSORY
Smoke Alarm Locator EI 159:
The Smoke Alarm locator is recommended for systems with
three or more Smoke / Heat Alarms as it helps quickly identify
the unit in alarm and reduces the impact of nuisance alarms.
Pressing the Smoke Alarm Locator button will silence all
interconnected alarms for 10 minutes, except those sensing
fire. It is easily installed between the interconnect and 0 volt
terminals.
GETTING YOUR ALARM SERVICED
If your Alarm fails to work after you have carefully read all the
instructions, checked the unit has been installed correctly, and
is receiving panel power contact Customer Assistance at the
address given at the end of this leaflet. If it needs to be returned
for repair or replacement put it in a padded box and send it to
"Customer Assistance and Information" at the nearest address
given on the Alarm or in this leaflet. Do not snap on the
mounting plate as this connects the battery and the unit may
beep or alarm in the post. State the nature of the fault, where
the Alarm was purchased and the date of purchase.
FIVE YEAR PRODUCT GUARANTEE
EI Electronics Ltd. guarantees this Alarm (excluding the
battery in the EI181/184/186 models) for five years from
date of purchase against any defect s that are due to
faulty materials or workmanship. This guarantee only
applies to normal conditions of use and service, and
does not include damage resulting from accident,
neglect,
misuse,
unauthorised
dismantling,
contamination howsoever caused. This guarantee
excludes incidental and consequential damage. This
guarantee does not cover costs associated with the
removal and/or installation of alarms. If this Alarm
should become defective within the guarantee period, it
must be returned to EI Electronics, with proof of
purchase, carefully packaged, with the problem clearly
stated. (see "Getting Your Alarm Serviced") We shall at
our discretion repair or replace the faulty unit.
Do not interfere with the Alarm or attempt to tamper with
it. This will invalidate the guarantee, but more
importantly may expose the user to shock or fire
hazards. This guarantee is in addition to your statutory
rights as a consumer.
Aico Ltd., Mile End Business Park,
Maesbury Rd, Oswestry, Shropshire SY10 8NN, U.K.
Telephone : 01691 657466
EI Electronics. Shannon, Co Clare, Ireland.
www.eielectronics
www.asis.com
15
17
SPECIFICATIONS
Supply Voltage: 10.5 to 30.0 Volts
(DC Only)
1. FREQUENT NUISANCE ALARMS OCCUR:
Standby Current: 7.5mA (m ax) @ 12 V; 10.0mA (max) @ 24 V.
(1) Close kitchen / bathroom door when in use.
Alarm Current: 58.0mA (max) @ 12 V; 60. 0mA (max) @ 24 V.
(2) Ensure that the alarm is sited at least 6m away from sources of
fumes.
Relay Contacts: 30 volts/1 amp resistive (normally open and
normally closed supplied). The unit is supplied with the relay
(3) Contamination from insects, paint or paint fumes may have
operating in continuous mode (i.e. relay is on while unit is
occurred. Clean the alarm as described in this booklet.
sensing smoke). To select pulse mode (relay turns on for 5
(4) If the problem persists, resiting of the unit should be
seconds only at start of smoke sensing), set jumper S1 to "P"
considered. Alternatively, replace the unit with an Optical unit
position.
(EI186/185), assuming that the problem is with an Ionisation type
The unit is also supplied with the relay in conventional, i.e. no
alarm (EI181/180).
contact resistance, mode. If required, 22K ohm can be
2. ALARM SOUNDS FOR NO APPARENT REASON:
connected in series with the C terminal and relay contact and
68K ohm between C and NC screw terminals by setting jumper
(1) Identify the alarm source. On interconnected units, the red
S2 to "R" position.
light on the cover will flash rapidly only on the unit which is the
source of the alarm.
Wiring: Wiring may be surface or recessed .
(2) Check for fumes, steam etc. from the kitchen or bathroom.
Cable: 4 core max resistance 20 ohms, provided specified
Paint and other fumes can cause nuisance alarms.
supply voltage is maintained at unit.
(3) Press the test/hush button to silence the Smoke/Heat Alarm
Test Button: Simulates the effect of fire and checks
electronics and horn.
for 10 minutes.
(4) If alarm does not stop, remove the unit (see figure 1). (Only
Power-on Indicators:
remove alarm with red light flashing, the others are probably
- Continuous green light on mounting plate for panel power
satisfactory).
- Red LED flashes every 40 seconds.
3. LOW BATTERY BEEPS:
Alarm output: Piezo horn 85dB (A) @ 3m
(On EI 181/184/186 only)
o
o
Standby Temp: 0
C - 40
C
If the battery is correctly connected and the unit has beeped for
over 20 minutes the battery is probably depleted. Obtain a new
Humidity: 10 - 90 % Relative HumidityInterconnect: Up to 20
units in total (EI 180, EI 181, EI 183, EI 184, EI 185, EI 186
battery, remove the alarm and replace the depleted battery. (see
units only) can be interconnected so that when one senses fire
figure 1).
all alarm. Relays switch on all units.
OTHER BEEPS:
Alarm Indicator: Red LED flashes rapidly only on units
(1) If the panel is providing power and replacing battery or
sensing fire.
cleaning unit has not stopped beeps, a fault may exist. Replace
Battery Back-Up: 9 Volt Alkaline Primary Battery will power
the unit (see figure 1).
the unit in standby for over 1 year without external power. Will
(2) The Ionisation/Heat units (EI 181/180/184/183) give two
power the unit for over 2 hours in alarm. Battery is monitored
beeps 10 minutes after the test/hush button is pressed.
for open circuit, short circuit and high impedance. The unit will
beep once a minute when it is starting to be depleted.
(3) If the Optical units (EI 186/185) beep without the red light
flashing at the same time, the chamber is defective. Clean the
Ionisation EI 181
chamber.
Sensor: Dual Ionisation Chamber
4. INTERCONNECTED ALARMS DO NOT ALL SOUND AND
Sensitivity: Complies with BS5446-1: 2000
THE RELAY DOES NOT SWITCH:
Source: 0.9 microcurie of Am 241
(1) Hold test button for 10 seconds after first alarm has sounded
to ensure signal is transmitted to all units. Relay should switch.
Combined Test/Hush Button: Tests and then hushes unit for
10 minutes. Automatically resets. Red LED flashes every 10
(2) Check that the green power light on the mounting plate is on.
seconds while in hush. At the end of the hush period unit gives
(3) Check panel and wiring.
a double beep.
18
Airspeed: No false alarms up to 10 m/s (22mph)
Insect Screen: Prevents insects or debris entering the
chamber
Dimensions: 145mm (d) X 55mm (h)
Weight: 380 grams
Ionisation EI 180
As EI 181 but without battery back-up
Optical EI 186
Sensor: Detects light scattered by smoke
Sensitivity: Complies with BS5446: Part 1: 2000
Ambient Light: Chamber design and electronic compensation
overcomes problems with stray light
Combined Test/Hush Button: Tests and then hushes unit for
10 minutes. Automatically resets. Red LED flashes every 10
seconds while in hush.
Airspeed: No effect
Insect Screen: Prevents insects and debris entering the
chamber
Automatic Self Test: Chamber is tested every 40 seconds
and unit beeps if it is degraded (without red light flashing at
same time)
4
Dimensions: 145mm (d) x 60mm (h)
Weight: 380 grams
or
Optical EI 185
4
As EI 186 but without battery back-up
Heat EI 184
4
Sensor: Fast response Thermistor
o
Sensitivity: 58 +/- 4
C (Response grade 1 as defined in EN54:
Part5)
4
Combined Test/Hush Button: Tests and then hushes unit for
10 minutes. Automatically resets. Red LED flashes every 10
seconds while in hush. At the end of the hush period unit gives
a double beep.
5
Airspeed: No effect
Contamination:
Much
less
affected
by
insects
and
contamination than Smoke Alarms
Dimensions: 145mm (d) x 65mm (h)
Weight: 380 grams
Heat EI 183
As EI 184 but without battery back-up
© EI Electronics 2001
19
Pages 1 & 14 to 21
B14090 Rev-1
12/03/01
TROUBLESHOOTING
20
LOW VOLTAGE PANEL
®
Professional
SMOKE & HEAT ALARM
IONISATION
HEAT
OPTICAL
ALKALINE 9 VOLT BATTERY BACK-UP
EI181
EI184
EI186
NO BATTERY ACKUP
EI180
EI183
EI185
INSTRUCTIONS
Contains vital information on unit operation and
installation. Read and retain carefully. If you are just
installing this unit, this leaflet
MUST
be given to the
householder.
LEAVE WITH USER
READ THIS FIRST
IDEALLY INSTALL IN THE CENTRE OF CEILING AT LEAST
300mm (1ft) FROM LIGHT FITTINGS. KEEP IONISATION
ALARMS AWAY FROM KITCHENS TO PREVENT NUISANCE
ALARMS. INTERCONNECT ALL ALARMS.
REMOVE UNIT FROM MOUNTING PLATE BY RELEASING
CATCH AS SHOWN IN FIG 1a.
EI181/184/186 ONLY: CHECK BATTERY IS CONNECTED TO
SNAP (SEE FIG 1b). BATTERY WILL NOT POWER THE UNIT
UNTIL IT IS SNAPPED ON TO THE MOUNTING PLATE.
ENSURE THE PANEL IS CORRECTLY CONNECTED TO ALL
TERMINALS OTHERWISE UNITS WILL NOT OPERATE
CORRECTLY. CHECK GREEN PANEL POWER LIGHT IS LIT ON
MOUNTING PLATE.
DO NOT FIT ACTUAL ALARM UNTIL ALL BUILDING WORK IS
COMPLETED TO AVOID CONTAMINATION. AFTER CHECKING
OPERATION, COVER SMOKE ALARM WITH DUST COVER
UNTIL REQUIRED FOR USE.
Continued Page 2
P/N B14090 Rev 1
1