Power Control - NEC LCD8205 - MultiSync - 82" LCD Flat Panel Display Control Manual

External control
Hide thumbs Also See for LCD8205 - MultiSync - 82" LCD Flat Panel Display:
Table of Contents

Advertisement

'0'-'0'-'0'-'4' (30h, 30h, 30h, 34h): Power mode is 4 types.
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Current power mode
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 5.1.3. "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet

5.4.3. Power control

1) The c on tr ol ler req ues ts t he m oni t or to c ontr o l m oni t or pow er .
Header
SOH-'0'-Monitor ID-'0'-'A'-'0'-'C'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'C (30h, 43h): Message length is 12 bytes.
Message
STX (02h): Start of Message
'C'-'2'-'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control command
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 5.1.3. "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet
=
OF= q
=
=
Header
SOH-'0'-'0'-Monitor
'0'-'E'
=
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) = When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'N'-'N': Message length
<Status>
0001: ON
0002: Stand-by (power save)
0003: Suspend (power save)
0004: OFF (same as IR power off)
0001: ON
0002, 0003: Do not set.
0004: OFF (same as the power off by IR)
= =
=
=
ID-'B'-
STX-'0'-'0'-'C'-'2'-'0'-'3'-'D'-'6'-
'0'-'0'-'0'-'1'-ETX
Message
STX-'C'-'2'-'0'-'3'-'D'-'6'-
'0'-'0'-'0'-'1'-ETX
K=
Message
Check
Delimiter
code
BCC
CR
Check
Delimiter
ode
BCC
CR

Advertisement

Table of Contents
loading

Table of Contents