5.3.2. How to change the "Brightness" setting.
The following is a sample of procedures to control the monitor, these are examples of "Get
parameter", "Set parameter" and "Save current settings".
Step 1. The controller requests the Monitor to reply with the current brightness setting and
capability to support this operation. (Get parameter)
Header
SOH-'0'-Monitor
ID-'0'-'C'-'0'-
'6'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'C' (43h): Message type is "Get parameter command".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the OP code page 0).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 5.1.3. "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 2. The monitor replies with current Brightness setting and capability to support this
operation.
Header
SOH-'0'-'0'-Monitor ID-'D'-'1'-'2'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'D' (44h): Message Type is "Get parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness max value is 100(0064h).
'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): Current Brightness setting is 50(0032h) .
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 5.1.3. "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Message
STX-'0'-'0'-'1'-'0'-ETX
Message
STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0'
-'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-
ETX
Check code
Delimiter
BCC
CR
Check code
BCC
Delimiter
CR