" FAN_CONTROL " Control procedure
7.47.
7.47.1. FAN_CONTROL Control
CMD
Data1
Command
Target
(0xF5)
(0x88)
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x3B) : ' FAN_CONTROL ' parameter
Value: Data value
1 : on
2 : auto
7.47.2. Current FAN_CONTROL state read
CMD
Data1
Command
Target
(0xF4)
(0x89)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x3B) : 'FAN_CONTROL ' parameter
CMD
Data1
Command
Value
(0xF1)
Command (0xF1) : Start send bit
Value : Current FAN_CONTROL getting value
1 : on
2 : auto
Data2
Data3
Monitor ID
CMD
(0x00)
(0xFE)
Data2
Data3
Monitor ID
CMD
(0x00)
(0xFE)
Data4
Data5
Parameter
Value
(0x3B)
Data4
Parameter
(0x3B)