Ipmi Shell - Dell PowerEdge 7250 User Manual

Product guide (.htm)
Hide thumbs Also See for PowerEdge 7250:
Table of Contents

Advertisement

The SOL Proxy will start automatically during system startup. Alternatively, you can go to directory
/etc/init.d and use the following command to manage the SOL Proxy service:
solproxy status
solproxy start
solproxy stop
solproxy restart
Uninstalling the BMC Management Utility
To uninstall the BMC Management Utility, perform the following procedures:
Log in as root.
1
Enter the following command to remove all the installed packages.
2
rpm -e osabmcutil
If you receive a success message, it shows that the BMC Management Utility is uninstalled.
3

IPMI Shell

IPMI Shell is a CLI console application and has no graphical user interface. Its commands and
options are specified using command line arguments only.
IPMI Shell supports out-of-band (OOB) access (over a LAN or through the serial port) to a single
system at a time, however, multiple IPMI Shell sessions can run simultaneously on the same
managed system. SeeFigure 3-2.
IPMI Shell allows a user with user-level BMC user privileges to:
Display the current power status
Display the 16-byte system GUID of the managed system
Display all field replaceable units (FRU) present in the system
Display the BMC firmware information
Display summary information about the event log
Display the logged events
In addition to the operations that can be performed by a user with user-level BMC user privileges,
IPMI Shell allows a user with operator-level BMC user privileges to:
Power on, reset, or cycle a managed system
Simulate a hard power off a managed system (forcing the system to turn off without shutting
down the operating system)
Delete the system event log (SEL)
Turn on/off the blinking system identification LED
30
BMC Management Utility

Advertisement

Table of Contents
loading

Table of Contents